  • IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
  • IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
  • IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
  • IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
  • IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
  • IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
Find Similar Products

Basic Info.

Model NO.
GD-IEC61034
Item Name
IEC 61034 Burning Analyzer Wire Flammability
Standard
IEC 61034;BS 6853;GB/T 17651
Application
Wire Flammability Test Equipment
Manual
Provide
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables

IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
 

Introduction:

IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables is the testing equipment measuring the smoke generated when the cable or optical cable is placed horizontally and burned under definite fire resource in the specified condition (3m3 chamber required by IEC61034).

IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables is important to measure the smoke generation from the value of light source penetration through the smoke generated when the cable is exposed to the specified standard fire source (ethanol 90±1%, methanol 4±1%, and distilled water 6±1%) 1L±0.01L is burned. 


Standard:

IEC 61034 - 1 & 2

- Measurement of Smoke density of cables burning under defined condition

- part 1: Test apparatus

- part 2: Test procedure and requirements

BS 6853

- Code of practice for fire precautions in the design and construction of passenger-carrying trains
GB/T 17651

 
Feature:

- Chamber's internal area is 3000mm±30mm and it's structured as a Cubic Enclosure with an appropriate fixed iron frame angle.

- It's configured with a door with test glass windows and on both faces of the opposite side there's a sealed transparent window (minimum 100mmX100mm) with a horizontal light measure system that allows light penetration.

- Designed to prevent direct sunlight exposure and severe weather changes in the Enclosure.

- Photocell and Light Source are located in the middle part of both windows of the wall surface on the opposite side to avoid physical contact.

- A lamp to provide regular light is installed.

- Two types of auto Filter systems (Carousel) are installed to calibrate the transmissivity of light automatically.

- The reduction of light by smoke is measured using Photocell.

- To verify the intensity of radiation to measure light change by self-emission, the IEC 61034 Burning Analyzer for Cables has been designed to fit various kinds of filters in the Light Source.  - Support system to allow separate fitting of Light Source and Photocell in the outer wall.

-The Light Source is a halogen lamp with a clean crystal lamp and tungsten filament.

- Average power : 100W, Average voltage: DC12v, Average velocity of light : 2000 lm~3000 lm, and Average color temperature : 2800K~3200K.

- The Receptor Photocell is selenium or silicone type and has a spectrum reaction conforming to Photopic Observer (similar to a human eye) of the International Commission on Illumination (CIE).

- A heating system is installed within the cube to swiftly match the initial test's standard temperature (25ºC±5ºC).

- We seek the tester's safety and convenience through an Auto ignition system.


Test Result

- Flameout time(min)

- Time to max Ao

- Min light transmittance (%)

- Add photo feature of carbonization area

 
Specification:

Product Name   IEC 61034 Burning Analyzer Wire Flammability Test Apparatus for Cables
Frame dimension   3,000(W) × 3,000(D) × 3,000(H)
Frame material   Stainless Steel SUS 301
Transparent sealed window   100 × 100 mm
Foundation Fixed   Fixture unit
Fixture unit   DC12V, 100W
Light Source Focus Angle   48 - 4.5  (degree)
Light Source Focus Intensity   1:20
Photo Cell Cell Type   Selenium Cell
Exhaust Blower Fan Flow   7 m3/min ~ 15 m3/min
Exhaust Blower Size   246(W) x 220(D) x 205(H) mm
Exhaust Blower Material   Stainless Steel (Inner Fan)
Exhaust Blower Power   AC220V, 60Hz, φ1, 210W
Power   AC220V, 60Hz
Rotation Angle   0~90 ± 5  (degree )
Control Rack Dimension   (W) 730 X (D) 650 X (H) 1,400

 