ASTM D217 Needle and Cone Type Grease Cone Penetrometer Testing Machine
Model |
GD-2801C |
GD-2801G |
GD-2801E1 |
GD-2801F |
GD-2801I |
Max.Penetration |
600 |
600 |
600 |
600 |
600 |
Resolution |
0.1mm |
0.1mm |
0.1mm |
0.1mm |
0.1mm |
Timing Control |
5,8,10,12,30,60s |
5,8,10,12,30,60s |
50,60s |
50,60s |
0~60s |
Temp. Control |
Automatic |
Automatic |
Automatic |
Automatic |
Automatic |
Test Samples |
Oil |
Wax |
Asphalt |
Asphalt |
Asphalt |
Type |
Common |
Multifuction |
Common |
Special |
Full Function |
With Water Bath |
Yes |
Yes |
Yes |
Yes, low temp. |
Yes, low temp. |
Standards:
GB/T 4509,GB/T 269,JTJ052,ASTM D217,ASTM D937,ASTM D5
What is the penetrometer test for Oil?
After loosening the test cone lock on the penetrometer, it can penetrate the grease for a period of five seconds. After these five seconds, the penetration depth of the test cone into the grease is determined with an accuracy of 0.1 mm.
What are the components of a needle penetration meter?
Equipped with grease masher, constant temperature bath, cold light source and a magnifier. Automatic controlled temperature bath for penetration determination. It is ideally used for hydrocarbons mixture, food industries, highway engineering, etc.
What are the precautions for the needle penetration tester?
1. To lift the needle link again, move the moving lever of the display to the upper end first, and then press the release button, instead of pulling it out while the needle link is locked, so as not to damage the connecting rod and the rod cover.
2. After each test is completed, the standard needle should be removed, oiled for protection and put into the protection.
3. When the instrument is not in use, the experimental equipment and instruments should be wiped clean and placed in a ventilated and dry place.
What is the debugging and installation method of the penetration tester?
1. After unpacking, check whether there is any failure due to transportation. the
2. Check whether there are missing parts according to the packing list, and notify the sales department of the company or the seller in time.
3. Plug in the power supply, turn on the power supply, and the display will display the time "5.0".
4. In order to ensure the detection accuracy, after 20 seconds of power on, press the <Manual> button of the instrument, and the needle bar assembly should be able to fall freely at this time.
5. The method of adjusting the level of the instrument is as follows: turn and adjust the branch angle, so that the air bubble in the horizontal bubble is in the center position. At this time, the working plane is already in the horizontal position.
Product name |
GD-2801C Automatic Needle Penetrometer for Petroleum |
Measurement range |
(0~600)penetration |
Timing device |
you can select 5 s, 8 s, 10 s, 12 s, 30 s, and 60 s; Timing error is less than ±0.1 s |
Resolution |
0.01 mm |
Penetration accuracy |
±1 penetration |
Standard needle |
50mm,2.5g±0.05g |
Heater power |
200 W |
Temperature control accuracy |
25±0.1 ºC (Note: The ambient temperature shall not be higher than 20 ºC) |
Temperature control mode |
by a high precision digital temperature controller |
Constant temperature bath |
Hard glass bath |
Bath stirring |
automatically stirred by a magnetic stirrer |
Standard cone |
102.5±0.05 g, as per GB/T269 and ASTM D217 |
Lifting support |
With coarse and fine adjustment functions; it is used to let the needle point just touch the sample surface. |
Power Supply |
AC (220 ± 10%) V, 50Hz, power consumption is not more than 300W |
Dimensions |
280 × 350 × 700mm (length × width × height) |
Others |
Equipped with a cold light source and a magnifier. It is convenient for instrument operation |
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd. is one of the leading manufacturers in China of geophysical instruments. Since its foundation, our factory has a group of highly qualified technical personnel specialized in development and well-trained workers, with advanced machinery and equipment. Our enterprise absorbs domestic and international advanced technology and management experience.
We have obtained trust from users, achieved reliable geological results, and won high reputation for the enterprise. Over many years, our products enjoy high reputation in the same industry relying on the advantages of light weight and practical usage, stable and reliable performance, and these products are selling well in domestic market and some of the products have been successively exported to many countries including Japan, Canada, France, Africa and other countries. Our factory have passed ISO9001 International Standard Quality System Certification in 2000, and passed Chongqing High-Tech Enterprise Certification in July 2010 which shows comprehensive improvement of our product quality, service and management.