• Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
  • Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
  • Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
  • Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
  • Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

After-sales Service: Lifetime Technical Support, Online Service
Warranty: 1 Year for CT PT Test Equipment
Type: CT PT Test Equipment
Accuracy Grade: 0.02%
Display: Touch Screen
Control: Manual or Computer
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
GDVA-405 CT PT Tester
Weight
Gross Weight:39kg
Power Source
AC220V
Accuracy
0.02%(Typical), 0.1% (Guaranteed)
Test Sample
All Type CT: M, P, Tpy, Bushing CT, Gis CT.etc
Test Standards
IEC60044-1, IEC60044-6, IEC61869, IEC60044-2, IEC60
Short Commissioning Times
Duration of The Automatic Test < 1min
Max Knee Point Voltage
60kv
Voltage Output
0.1-180V (AC)
Current Output
0.001-5A(RMS)
Power Output
500va
Transport Package
Plywood Case
Specification
56*45*44CM
Trademark
CHONGQING GOLD
Origin
Chongqing, China (Mainland)
HS Code
9030849000
Production Capacity
100PCS/Month

Product Description

GDVA-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
Current/voltage transformers can change high voltage into low voltage and large current into small current for measurement or protection system. Its function is mainly to convert high voltage or high current into standard low voltage (100V) or standard small current (5A or 1A, both refer to rated value) in proportion, so as to realize the standardization and miniaturization of measuring instruments, protection equipment and automatic control equipment. change. At the same time, the transformer can also be used to isolate the high voltage system to ensure the safety of people and equipment.

 
Test items
---GDVA-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

 
Test items for Current Transformer(CT) Test items for Potential Transformer(PT)

Turn ratio detection

Ratio and angle error check

Polarity test

Excitation characteristic test

Secondary winding resistance measurement and secondary burden measurement

5% and 10% error curve measurement

Transient characteristics analysis

Automatic nameplate inference

Knee point voltage/current

Accuracy Limit Factor (ALF)

Instrument security factor (FS)

Secondary time constant (Ts)

Remanence coefficient (Kr)

Accuracy

Saturation and desaturation inductance

Knee point electromotive force

Limit electromotive force

Area factor

Iron core analysis and core hysteresis loop measurement

Turn ratio measurement

Ratio and angle error check

Polarity test

Excitation characteristic test

Primary winding resistance test

Secondary winding resistance test

Secondary burden measurement


Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

Advanced Operations and Analysis Software for GDVA-405 Current transformer test equipment
---GDVA-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

 
Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

Technical Index
---GDVA-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

 
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, IEC61869,C57.13
Voltage output  0.1-180V (AC)
Current output 0.001-5A(RMS)
Power output 500VA
Max. knee voltage measurement 60kV
Current measurement Range 0-10A (automatically change  range in 0.1/0.4/2/10A)
Current measurement error <±0.1%+0.01%FS
Voltage measurement range 0-200V (automatically change range in 1V/10V/70V/200V)
Voltage measurement error < ±0.1%+0.01%FS
Turns ratio measurement Range 1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement   error: ±2min;  resolution:0.01min
Winding resistance measurement range 0-8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
error: < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement -50-100 Celsius degree; error<3 Celsius degree
CT Secondary burden range 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
error: <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
PT Secondary burden range 0-80kohm (automatically change range in 800ohm/8kohm/80kohm)
error: <0.2%RDG+0.02%FS

Maximum resolution : 0.1ohm
PT ratio measurement range

1-35000,

1-10000 error<0.1%, 

10000-35000 error<0.2%

PT ratio error measurement Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Memory capacity >1000 groups test results

Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment
Company Profile

Gdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test EquipmentGdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test EquipmentGdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test EquipmentGdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test EquipmentGdva-405 0.02% Accuracy Portable Transformer CT PT Tester Current Transformer Test Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters