Customization: | Available |
---|---|
After-sales Service: | Lifetime Technical Support |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This GD-R2223 Oxidation Stability Bath unit measures the induction period for oxygen in gasoline, and allows the weight of gum and residue in aviation fuel to be determined by direct weighing.Comprising a heated water bath with reflux condenser, a cold water plunge tank for cooling test vessels after each test, and an integral system for charging oxidation vessels prior to test. The GD-R2223 Oxidation Stability Bathprovides automatic monitoring of up to four pressure test vessels. High quality pressure transducers and system components ensure reliable operation and fully traceable results
1. The software automatically records the conductivity change curve, and determines the induced inflection point by calculating the second derivative of the curve;
2. After the test, the result of the induction reaction time is stored in the database together with the test process curve for query;
3. In addition to measuring the induced reaction time, the software also allows the evaluation of the so-called stabilization time, the time required for the conductivity to reach a specific value
4. The software can also re-evaluate each test curve. Select a section of curve for evaluation by setting the evaluation time range to avoid some data abnormalities due to cleaning, specimen or other reasons
5. The database can save all data related to the test, including conductivity curve, induced reaction time, method used, test start and end time, etc.
6. You can query test data by setting query conditions;
7. The software also has the functions of multi-curve comparison and curve analysis;
8. Display mode: curve/digital two modes
9. Temperature and flow can be calibrated by testing software
10. Working unit: four tubes
11. Each sample is controlled individually and can be set automatically according to requirements.
Flow range |
8~12L/h |
Flow accuracy |
± 10% |
Test range |
0~800 μS/cm |
Resolution |
0.1μS / cm |
Gas source | special diaphragm pump 10L/H |
Temperature control method | electric heating rod |
Working temperature | 50~150 °C |
Temperature control accuracy | ± 0.1 ° C |
Working power | AC220V ± 10% 50HZ |
Power | 1.1KW |
The result of processing |
computer automatic measurement, storage |
If you have any questions about this GD-R2223 Fats ISO6886 Oxidation Stability Bath or the instruction, please contact us in time. We will serve you wholeheartedly!