Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
IEC 60695 Glow Wire Tester for Household Appliances
Introduction:
Glow wire tester is designed and produced in accordance with the standards "Glow Wire Test Method" of IEC60695-2-10, GB/T5169.10-2006, GB/T5169.13-2006, and GB4706.1. It is suitable for the requirements of fire hazard testing of electronic and electrical products, household appliances and materials, and simulates the thermal stress caused by heat or ignition sources such as burning components or overload resistance in a short time.
IEC 60695 Glow wire tester adopts the integrated design of the cavity part and the control part, which is convenient for installation and debugging. The outer shell and important parts of the test chamber are made of stainless steel, which is resistant to smoke and gas corrosion. The automatic adjustment control system adopts SCR current to achieve the purpose of precise temperature control. The time and temperature can be displayed digitally, which is convenient for observation and recording. It is stable in use and reliable in test results.
Standard:
IEC60695-2-10 ~ 13
GB / T5169.10-13-2006: Glowing / hot-wire based test methods, glow-wire test apparatus and common test methods
UL 746A
IEC829
DIN695
VDE0471
Technical Parameters:
Now the test chamber size to see the table below
Model |
Standard |
The casing volume m³ |
Overall dimensions (mm) |
Weight |
Configuration |
GD-5169 |
GB4706.1 GB/T5169.4 |
0.1 |
W710xD365xH760 |
30KG |
Φ 0.5 armored thermocouple |
GD-60695 |
IEC60695 and IEC335 |
0.5 |
W1000 x D600 x H1260 |
50KG |
|
GD-746 |
UL746 |
0.75~1 |
W1200 x D600 x H1260 |
2. Temperature range: 500 ~ 1000 ºC, digital display adjustable,
3. Temperature error: ± 10 ºC (500 ~ 750 ºC); ± 15 ºC (750 ~ 1000 ºC), temperature measuring instruments Accuracy ± 0.5 magnitude.
4. Temperature sensors: Φ0.5K type armored thermocouple, thermocouple imports.
5. Pressure applied to the specimen: 0.8N ~ 1.2N, and limit the indentation depth of at least 7mm.
6. Timing range: 0 to 99 minutes 99 seconds adjustable,
7. And having Shi burning time (Ta, generally according to standards set to 30), second holding burning time (Ti) and the flame goes out time (Te) of the timer;
8. Time error: ± 1s.
9. Ignited bedding layer: 10mm thick white pine wood, covered 12g / m2 ~ 30g / m2 standard tissue paper, from under the glow wire 200mm ± 5mm
10. Instrument operation is a simple, stable and reliable temperature measurement system and automatic temperature compensation.
11. Power supply: AC220V ± 10% / 50Hz. (Other power specifications can be customized)