The conical calorimeter is designed in a separate cabinet, and the analysis cabinet can be moved. It can not only be used in the test of the conical calorimeter, but also be connected to the large-scale heat release rate test system, such as single combustion test device, solid room fire and cable fire classification test, which conforms to ISO 5660, ASTM E1354, GB/T16172 and other test standards.
Integrated test body and 19-inch analysis cabinet, embedded PC 15-inch industrial touch screen computer, used for the whole control and test process;
The cone heater is rated at 5000W, and its thermal output is 0 ~ 100kW/m2. It is controlled by PID temperature controller, and the radiation cone can be placed horizontally or vertically.
The sample box can store samples with a maximum of 100mm x 100mm x 50mm;
Sample weighing range 0 ~ 2000g;Accuracy: 0.1g (different range and accuracy can also be provided according to customer requirements);
Ignition system is no less than 10KV high-voltage spark generator, using rotating cylinder automatic positioning;
Paramagric oxygen analyzer, range 0-25%, response time: 4 seconds, linear deviation: ≤0.5% FS, repeatability: ≤50 PPM O2, sensitivity drift: ≤ 0.1 vol.% O2/ week or ≤ 1% measured value/week (not cumulative), the smaller of the two, detection limit: ≤50 PPM O2;
Non-dispersive infrared CO and CO2 analyzer CO: 0 ~ 1%;CO2:0 ~ 10%, measurement principle: infrared absorption, response time: 2.5 seconds, linear deviation: ≤1% FS, repeatability: ≤0.5% FS, zero drift: ≤1% FS/ week, detection limit: ≤0.5% FS;
Smoke density analysis USES laser system to measure smoke density. The system consists of photodiode, he-ne laser, main detector and auxiliary detector.
The exhaust system is composed of fan, smoke collection hood, exhaust pipe and orifice plate flowmeter, etc. The flow rate of smoke exhaust fan is adjustable from 0 to 50g/s with an accuracy of 0.1g/s.
The annular sampler is installed in the air inlet pipe 685 mm away from the smoke collecting hood. There should be 12 small holes on the sampler to homogenize the air composition.
Specifications are displaying in table:Basic Specifications | |
Exhaust | 50 l/s |
Size | 1750(W) × 600(D) × 2800(H) |
Weight | 450 kg |
Power | 220 V AC, 60 Hz, 30 A |
Test Results | |
Parameters | Unit |
Heat Flux | kW/m2 |
Exhaust duct flow rate | L/s |
C factor | L/kgmK |
Ignition time and extinguisment time | s |
Total oxygen consumption | g |
Total Smoke Release | m/m2 |
Mass loss and Mass loss rate | g, g/s |
Heat release rate | MJ/kg, kw/m2 |
Effective heat of combustion | MJ/kg |
Carbon monoxide yield | kg/kg |
Carbon dioxide yield | kg/kg |