• Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
  • Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
  • Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
  • Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
  • Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
  • Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester

Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester

After-sales Service: Lifetime Technical Support, Online Service
Warranty: 1 Year
Ratio Measurement Range: 1-10000
Group Measurement: 1-12
Phase Measurement Error: 1 Degree
Ratio Measurement Error 1: 1-2000 ± 0.2%Rdg
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDBC-901
Ratio Measurement Error 2
2000-10000 ± 0.5%Rdg
Test Voltage
0~80V, Frequency 50Hz
Power Supply
AC220V ± 10%, 50Hz/60Hz
Environment Temperature
0-50°c
Humidity
≤85%R
Weight
22kg
Transport Package
Standard Case
Specification
22Kg
Trademark
GOLD
Origin
Chongqing, Gold
HS Code
9030849000
Production Capacity
200piece/Month

Product Description

GDBC-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester

Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester

Introduction of Turns Ratio Tester:

  • The voltage ratio measurement for three or singe phase transformer 

  • The group vector measurement for three phase transformer.

  • The polarity measurement for single phase transformer or CT/PT

  • Voltage ratio error calculation

  • Current transformer ratio measurement

  • Excitation current measurement in ratio testing

  • Reproduction the AC test voltage from power source to reduce the effects of bad power source

  • Save the test results in the memory internal the tester

  • Print the test results by micro printer

  • Reverse connection detect unit to prevent the high voltage injected to operator

  • Over current protection unit integrated in software and hardware

  • Upload the test results to PC by RS232 and make word report by software

 

Specifications of Turns Ratio Tester:

1 Item Name GDBC-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
2 Ratio measurement range 1-10000
3 Group measurement 1-12
4 Phase measurement error 1 degree
5 Ratio measurement error 1-2000 ± 0.2%RDG   2000-10000  ± 0.5%RDG
6 Test voltage 0~80V, frequency 50Hz
7 Power supply AC220V ± 10%, 50Hz/60Hz
8 Environment temperature 0-50°C
9 Humidity ≤85%R
10 Dimension 58*45*36CM
11 Weight 22Kg

Application Field:

Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
Real Pictures:
Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester
Customer Feedback:

Gdbc-901 CT Polarity Test Three Phase Power Transformer Turns Ratio Tester


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now