AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for High Voltage Capacitive Voltage Divider
Still deciding? Get samples of US$ 4000/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
  • AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
  • AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
  • AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
  • AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
  • AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
Find Similar Products
  • Overview
  • Excerpt on Voltage Divider
  • Principles of Operation
  • Product Parameters
  • Problems and Solutions
Overview

Basic Info.

Model NO.
FRC
Type
High Voltage Meter Capacitive Voltage Divider
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Weight
10-31kg
Power Source
AC220V
Product Name
High Voltage Meter Capacitive Voltage Divider
Measuring Voltage 1
AC 50/100/200/300kv
Measuring Voltage 2
DC 50/100/200/300kv
Voltage Divider Resistance
240-1200mΩ
Voltage Division Ratio
3000:1-15000:1
Components
Voltage Divider&Cabinet
Transport Package
Wooden Case
Specification
as different requirements
Trademark
GOLD
Origin
Chongqing, China
Production Capacity
200sets/Month

Product Description

AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter

AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter

Excerpt on Voltage Divider

 

AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
In electronics, a voltage divider (also known as a potential divider) is a passive linear circuit that produces an output voltage (Vout) that is a fraction of its input voltage (Vin). Voltage division is the result of distributing the input voltage among the components of the divider. A simple example of a voltage divider is two resistors connected in series, with the input voltage applied across the resistor pair and the output voltage emerging from the connection between them.

Resistor voltage dividers are commonly used to create reference voltages, or to reduce the magnitude of a voltage so it can be measured, and may also be used as signal attenuators at low frequencies. For direct current and relatively low frequencies, a voltage divider may be sufficiently accurate if made only of resistors; where frequency response over a wide range is required (such as in an oscilloscope probe), a voltage divider may have capacitive elements added to compensate load capacitance. In electric power transmission, a capacitive voltage divider is used for measurement of high voltage.

 
 

Principles of Operation

 

Digital high voltage meter consists of two parts: voltage divider and digital voltmeter. The voltage divider is a passive resistive-capacitive voltage divider, which is composed of high-precision low-temperature-drift resistor and precision capacitor. The digital voltmeter consists of true rms circuit, peak measurement circuit and digital display. Voltage divider and digital voltmeter with coaxial cable connection, high voltage through the divider voltage divider sampling sent to the digital voltmeter, through the function switching button, respectively, the detection of the corresponding value and display in the digital display, can be read out directly measured DC, AC RMS, AC peak and AC voltage. The instrument is easy to operate and has high measuring accuracy.
 
AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
AC DC High Voltage Meter Capacitive Voltage Divider Electrostatic Voltmeter
 

Product Parameters

 

Model FRC-50 FRC-100 FRC-200 FRC-300
Measuring Voltage(KV) AC 50 AC 100 AC 200 AC 300
DC 50 DC 100 DC 200 DC 300
A accuracy AC 1.5   DC 1
B accuracy AC 1   DC 0.5
C accuracy AC 0.5   DC 0.5
Voltage Divider Resistance(MΩ) 240 400 800 1200
Voltage division ratio 3000:1 5000:1 10000:1 15000:1
Use conditions temperature 0-40°,
humidity: ≤85%
Size
(mm)
voltage divider Φ94*440 Φ94*610 Φ94*1060 Φ94*1540
cabinet 510*240*290 670*240*290 1110*270*290 1600*300*330
Weight(kg) 10 17 21 31

 

Problems and Solutions

 

Problem Solution
 Test results are too much deviation. Check whether the coaxial cable is well connected.
There is more obvious discharge sound when measuring. Check whether the ground is good.
HV divider may be damp, Please wipe the shell with a dry cloth and then blow it for five minutes with blower.