• High Quality Current Transformer Tester CT PT Test Set
  • High Quality Current Transformer Tester CT PT Test Set
  • High Quality Current Transformer Tester CT PT Test Set
  • High Quality Current Transformer Tester CT PT Test Set
  • High Quality Current Transformer Tester CT PT Test Set
  • High Quality Current Transformer Tester CT PT Test Set

High Quality Current Transformer Tester CT PT Test Set

After-sales Service: Life Time Support
Warranty: 1 Year for High Quality CT PT Test Set
Type: CT PT Analyzer
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 7000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • CT Test Items:
  • PT Test Items:
  • Usages of CT/ PT Analyzer:
Overview

Basic Info.

Model NO.
GDVA-405
Display
Digital
Control
Digital Control
Weight
15kg
Power Source
AC220V
Product Name
High Quality Current Transformer Tester CT PT Test
Usage
Transformer Tester
Test Standards
IEC60044-1/2/5/6
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

 High Quality Current Transformer Tester CT PT Test Set


High Quality Current Transformer Tester CT PT Test Set
High Quality Current Transformer Tester CT PT Test Set

CT Test Items:



1. The excitation characteristic and parameters of the current transformer need to be tested.

2. The turns ratio between the primary and secondary windings needs to be measured.   

3. The ratio and phase angle errors must be checked.   

4. The polarity markings should be verified.

5. The resistance of the windings should be measured.   

6. The burden of the secondary loop needs to be determined.

7. An error line curve test for the protection current transformer is required.

8. The transient parameters of the current transformer must be measured.

9. An attempt should be made to deduce the nameplate specifications of the current transformer.

10.The saturation hysteresis loop curve of the current transformer needs to be plotted through measurements.

 

PT Test Items:



1. The ratio between the number of turns in the primary and secondary windings needs to be determined through measurement.   

2. Testing is required to check for any ratio error and phase displacement error.

3. A test must be conducted to ensure the polarity markings are correct.   

4. A test should be performed to determine the loading characteristics of the secondary winding.

5. The resistance of the windings should be measured through testing.


 

Usages of CT/ PT Analyzer:



1. The nameplate information of the current transformer should be verified.

2. The electrical parameters of the current transformer need to be evaluated under working load conditions.  

3. An analysis of the transient performance parameters of the current transformer is required.

4. Calibration of the ratio and phase error of the current transformer is needed.   

5. The current transformer needs to undergo standard tests to ensure proper functioning.

 

High Quality Current Transformer Tester CT PT Test Set

More Details for CT PT Analyzer:
 
High Quality Current Transformer Tester CT PT Test Set
High Quality Current Transformer Tester CT PT Test Set

 

 Standard Configuration for CT/PT Analyzer:

Name  Quantity  Description
Host machine  1  
3M mask cable  2 Test cable for power out and CT
secondary
connection
10M mask cable 1 Test cable for CT primary connection
Grounding cable 1  
Big test pliers   2 One red and one black
Test gasket  4 Two red and two black
Test pin  4 Two red and two black
Test pliers 12 Three red and nine black
Short connection cable  1 Including six connection terminals
3A fuse 3  
Power cable 1  
Accessories bag  1  
Production disk 1 Include Analysis application and user manual
User manual 2  
Inspection report 1  
Pass certificate 1  
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters