Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials

Product Details
Customization: Available
After-sales Service: All Life Technical Supports
Warranty: 12 Months
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials
  • Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials
  • Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials
  • Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials
  • Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials
  • Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials
Find Similar Products

Basic Info.

Model NO.
GD-BS476-7
Standard
BS 476-7
Electrical
230 Volts Nominal 10 AMPS
Ambient Temperature
Operating 10 to 35 Degree
Gas Supplies
Propane and Air Compressor
Testing Room
400 M3
Size
1220 mm (W) X 550 mm (D) X 1920 mm (H)
Weight
About 200kg
Heat Flux Meter: Range
0 ~ 50 Kw/M2
Surface Emissivity
0.95±0.05
The Specimen Holder Assembly Is Located
88-92 Degree
The Radiation Panel
Sullied with an Gas-Air Mixture
Manual
Provide
Shipping Port
Shanghai
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

Surface Flame Spread Tester Chamber Flammability Analyzer For Building Materials

Surface Flame Spread Tester Chamber Flammability Analyzer for Building Materials

Usage:

Protective clothing flame spread tester is according to ISO 15025 standard to design and produce. Surface Flame Spread Tester Chamber Flammability Analyzer For Building Materials can test the flame spread state under a small flame. It is used to simulate the protective clothing is at the risk of ignition to assume the flame spread performance. It is also suitable for fabric material or other similar functional uses of combustible materials.

 

Introduction:

BS 476 Part 7 specifies a method of test for measuring the lateral spread of flame along the surface of the specimen of a product orientated in the vertical position under opposed flow conditions, and a classification system based on the rate and extent of the spread of flame. Surface Flame Spread Tester Chamber Flammability Analyzer For Building Materials provides data suitable for comparing the end-use performances of essentially flat materials, composites, or assemblies, which are used primarily as the exposed surfaces of walls and ceilings.

 

Application:

Building Materials

Rail

 

Standard:

>>> BS 476-7---Fire tests on building materials and structures. Method of test to determine the classification of the surface spread of flame of products

 

Specification:

1, Surface Flame Spread Tester Chamber Flammability Analyzer For Building Materials consists of a radiation panel mounted vertically in a surround and supported on a framework.

2, The radiation panel is sullied with a gas-air mixture.

3, The radiation panel is 850mm square for a porous refractory type burner block designed to give efficient combustion of the air-gas-air mixture, with no flaming occurring on the face of the panel under operational conditions.

4, The radiation panel and its surround are supported on a framework so that the center of the panel is about 1250±100mm above floor level.

5, A specimen holder and a pilot flame arrangement mounted to one side of the apparatus.

6, The specimen holder comprises a water-cooled steel frame with water-cooled face plates. The face plates overlap the specimens by 20±2mm on their top and bottom edges and over the vertical edge adjacent to the radiation panel.

7, A spring-loaded clamp is positioned to clamp the specimen against the face plates.

8, The portable water supply to the specimen holder ensures the maximum temperature does not exceed 35ºC at the outlet from the specimen holder.

9,  The specimen holder assembly is located at 90±2° to the face of the radiation panel and in such a way that the faces of the top and bottom guides of the specimen holder are in the same plane as the inside face of the surround to the radiation panel.

10, The height of the specimen holder is hinged to allow it to be swung horizontally, away from the face of the radiation panel between tests, from the test position to the standby position, and vice-versa.

11, The pilot burner consists of a steel tube.

12, The gas and air supply lines to the radiation panel contain flow meters, pressure regulators, control valves, and safety devices.

13, Heat Flux Meter: Range : 0 ~ 50 kw/m2; Surface emissivity : 0.95±0.05.

14, Dummy calibration board with holder, calibrated heat flux meter, and mounting.

 

Installation Requirement:

Item name  Surface Flame Spread Tester Chamber Flammability Analyzer For Building Materials
Electrical  230 volts Nominal 10 Amps
Ambient Temperature  Operating 10°C to 35°C  
Gas Supply  Propane and air compressor
Testing Room  400m3
Size  1220 mm (W) x 550 mm (D) x 1920 mm (H)
Weight

 about 200kg

 

 