Transformer High Voltage Oil Immersed AC DC Hipot Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for High Voltage AC DC Hipot Tester
Still deciding? Get samples of US$ 3500/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Transformer High Voltage Oil Immersed AC DC Hipot Tester
  • Transformer High Voltage Oil Immersed AC DC Hipot Tester
  • Transformer High Voltage Oil Immersed AC DC Hipot Tester
  • Transformer High Voltage Oil Immersed AC DC Hipot Tester
  • Transformer High Voltage Oil Immersed AC DC Hipot Tester
  • Transformer High Voltage Oil Immersed AC DC Hipot Tester
Find Similar Products
  • Overview
  • Product Description
  • Model Selection
  • Features
  • More Details
  • Customer use
Overview

Basic Info.

Model NO.
GDJZ
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Power Source
AC220V
Product Name
High Voltage Oil Immersed AC DC Hipot Tester
Composition
Controller Oil Type Transformer
Application
Oil Type Hipot Tester
Usage
Hipot Tester
Hi-Pot Tester Capacity
3kVA-50kVA
Transformer Type Optional
AC Type, DC Type or AC DC
Hi-Pot Tester Type
Oil Type, Oil-Immersed Transformer
Function
Dielectric Withstand Test
Transport Package
Wooden Case
Specification
As different size
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month

Product Description

Transformer High Voltage Oil Immersed AC DC Hipot Tester

Transformer High Voltage Oil Immersed AC DC Hipot Tester

Product Description

A withstand voltage tester is an instrument used to test the insulation strength of electrical equipment, whether the equipment can maintain insulation under high voltage without electric shock or leakage. The withstand voltage tester usually uses DC or AC high voltage signals for testing, and can test the insulation strength of various electrical equipment (such as cables, transformers, switches, sockets, etc.).

AC withstand voltage test equipment, commonly known as AC DC transformer withstand voltage tester, is characterized by small size, light weight and sturdy structure. It is equipped with a full range of functions, has strong versatility, and is very convenient for users to use.

Model Selection
  • Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.

  • The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order.

    Capacity GDJZ-50 Series GDJZ-100 Series GDJZ-150 Series
    KVA AC DC AC DC AC DC
    3kVA 50KV 70KV        
    5kVA 50KV 70KV 100KV 140KV    
    10kVA 50KV 70KV 100KV 140KV 150kV 210KV
    15kVA 50KV 70KV 100KV 140KV 150kV 210KV
    20kVA 50KV 70KV 100KV 140KV 150kV 210KV
    25kVA 50KV 70KV 100KV 140KV 150kV 210KV
    30kVA 50KV 70KV 100KV 140KV 150kV 210KV
    50kVA 50KV 70KV 100KV 140KV 150kV 210KV
    Different Types of High Voltage Test Transformers
    Transformer High Voltage Oil Immersed AC DC Hipot Tester
     
    Oil-immersed transformer Dry-type transformer Gas-filled transformer
     
    1. Oil-immersed transformer:

    * This type of transformer uses insulating oil as the main insulating and cooling medium.
    * Oil-immersed transformers are usually used in higher voltage levels and larger capacities.
    * Oil-immersed transformers are relatively simple to maintain and low cost, but oil aging and possible leakage problems need to be considered.

    2. Dry-type transformer:

    * Dry-type transformers use dry insulation materials such as epoxy resin, cellulose material or vacuum pressure impregnation (VPI) treated insulation paper as the insulating medium.
    * Suitable for occasions where space is limited or good fire resistance is required.
    * The maintenance cost of dry-type transformers may be higher than that of oil-type transformers, but they have advantages in safety and reliability.

    3. Gas-filled transformer:

    * Gas-filled transformers use gas (usually nitrogen or sulfur hexafluoride (SF6)) as the insulating and/or cooling medium.
    * SF6 gas has excellent insulation properties and thermal conductivity and is commonly used in high-voltage and extra-high-voltage transformers.
    * Gas-filled transformers can be designed as fully enclosed switchgear (GIS), suitable for urban environments and underground facilities.
    Features

    1. The use of a new type of time relay allows for a wider timing range (1second to 99 hours).
    2. The adoption of a new type of current relay ensures more accurate and reliable timing, safeguarding personal and equipment safety.
    3. The power frequency test transformer is equipped with new insulation that is moisture-proof, impact-resistant, and has a high insulation grade.

    4. The structure is rationally designed, compact in size, and lightweight.

    More Details

    Transformer High Voltage Oil Immersed AC DC Hipot TesterTransformer High Voltage Oil Immersed AC DC Hipot TesterTransformer High Voltage Oil Immersed AC DC Hipot Tester

    Customer use

    Transformer High Voltage Oil Immersed AC DC Hipot Tester

     

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier