• High Precision Standard High Voltage Power Supply with Automated Calibration System
  • High Precision Standard High Voltage Power Supply with Automated Calibration System

High Precision Standard High Voltage Power Supply with Automated Calibration System

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Calibration High Voltage Power Supply
Type: High Voltage Power Supply with Automated Calibrati
Accuracy Grade: 0.2
Load Way: Electronic Load
Loading Method: Static Load
Samples:
US$ 10000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDAP
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC380V
Product Name
High Voltage Power Supply
System Output Voltage Range
0 ~ 100kv / 0 ~ 200kv (Can Be Customized)
Reading Error
0.2% Rdg + 2D
Operation Mode
Touch Screen
Output High Voltage Frequency
30Hz ~ 300Hz
System Input Power Supply
AC380V/AC220V
Transport Package
Wooden Case
Specification
ask the salesman
Trademark
GOLD
Origin
Chongqing. China
Production Capacity
200 Sets/ Month

Product Description

High Precision Standard High Voltage Power Supply with Automated Calibration System

High Precision Standard High Voltage Power Supply with Automated Calibration System

Introduction of HVPS

The whole voltage withstand test set consists of operation console, 2 sets of program-controlled frequency conversion power supply, 2 sets of 200KV step-up transformer and 2 sets of 200KV pure capacitive voltage divider. All the boosting process control and reading are completed by the control computer of the operation console. In the test before the start of the operating console computer software set test mode, test voltage and high voltage operation time, when the test process is started, the operating console computer to program control frequency conversion power supply to send boosting instructions to control its output voltage boosting, operating console computer real-time acquisition of 2 sets of 200KV voltage divider of the low-voltage arm of the output voltage, in the automatic boosting mode, the wireless high-voltage phasor calibration devices In automatic boosting mode, the wireless high-voltage phase checker verification device will control the phase angle difference between the two high-voltage while controlling the voltage rise to ensure that the phase angle is in line with the control requirements of the working conditions before boosting. After reaching the target value in manual boosting mode or automatic boosting mode, the amplitude of the two high voltages and the phase angle difference between the two high voltages can be adjusted through the test console.


Product features

The GDAP series high precision standard high voltage power supply incorporates an automatic calibration system, allowing calibration and testing of high voltage measurement instruments such as voltage dividers, high voltage meters, and series resonance systems.

It offers a stable and reliable high voltage source with adjustable frequency and amplitude, ensuring accurate and dependable testing. Additionally, it includes a high precision measurement system to enhance the accuracy and reliability of the test results.

The GDAP series provides solutions specifically designed for high voltage instrument calibration applications. These solutions offer excellent stability, a low ripple coefficient, and precise high voltage readings.

This system is responsible for generating a high-precision AC high-voltage power supply with variable frequency. It also monitors the output power supply through a high-precision broadband voltage divider. During the calibration process, the system automatically adjusts the voltage, records the accurate reading of the target point, and simplifies the calibration process for the calibrator. Moreover, the system can automatically generate a Word format report based on the recorded standard reading value and the test reading value.

High Precision Standard High Voltage Power Supply with Automated Calibration System

Technical Index
System input power supply 10KVA above the system AC380V three-phase four-wire system, input power frequency: 45HZ ~ 65HZ

10KVA and below system AC220V supply, input power frequency: 45HZ ~ 65HZ
System output voltage range 0 ~ 100KV / 0 ~ 200KV (can be customized)
Output high voltage frequency 30HZ ~ 300HZ
Broadband measurement voltage divider capacity 100pF
Broadband voltage divider operating frequency 30HZ ~ 300HZ
Calibration system measurement reading error 0.2% RDG + 2D
Operation mode touch screen
Calibration system working environment requirements temperature 0 ~ 50 ºC humidity less than 80%
Output voltage waveform distortion rate of less than 1% typical value, the guaranteed value of less than 1.5%

Actual picture
High Precision Standard High Voltage Power Supply with Automated Calibration System
Connection schematics
High Precision Standard High Voltage Power Supply with Automated Calibration System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters