• IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
  • IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
  • IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
  • IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
  • IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
  • IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Circuit Breaker Analyzer
Appication: Sf6 CB, Vacuum CB, Normal CB
Test Standard: IEC62271
Speed Measurement: 2 M/S
Coil Current Measurement Range: 0~20A
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGK-307 Circuit Breaker Analyzer
Display Type
Analog and Digital
Operating Temperature
0~40c
Measuring Range
Time, Speed, Distance
Time Measurement Range
4000ms
Internal DC Power Source
Voltage: 12~265V; Current:0~20A
Channel
12 Channels
Measured Parameters
Almost All Parameters of Circuit Breaker
Application Field
Electrical Industry, Circuit Breaker Manufacturer
Usage
Test Parameters of High Voltage Circuit Breaker
Transport Package
Wooden Case for Circuit Breaker Analyzer
Specification
44*26*50cm
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
500sets/Month

Product Description

IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

Introduction: 

IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

1. Circuit Breaker Tester is used for testing, analyzing and assessing power system circuit breakers, mechanical characteristics of load switches and isolated switches and other AC high voltage switches, contact resistance, Arcing contacts and vibration characteristics etc.

2. The functions of Circuit Breaker Tester cover all testing items of high voltage circuit breaks.


Comparing with the traditional circuit breaker tester, this Circuit Breaker Analyzer has the following unique advantages:

1. The integrated vibration test function of Circuit Breaker Analyzer provides a new means of detection circuit breaker mechanical characteristics for users, compared to traditional time measurement and speed measurement, the vibration fingerprint detection is easier and more efficient.

2. The vibration fingerprint test results contain richer information of circuit breaker operation, for potential risk of failure or faulty breakers, it can locate the fault position quickly. 

3. The vibration tests do not need to change the original line connection, so the users can complete the charged detection of mechanical characteristics of circuit breaker.

4. Arcing contact analysis module allows users to automatically assess the degree of loss of inside Arc suppression contact of circuit breaker without disassembly.

5. Users can use Circuit Breaker Analyzer to complete the contact resistance tests, do not need to buy contact resistance tester separately.


Features:
IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer


1. Measurement of closing time, opening time, time spread between poles, time spread between units of one pole, bounces etc. 
2. Measurement of closing speed, opening speed and average speed.
3. Measurement of clearance between open contacts, over travel, overshoot travel and total travel.
4. Measurement of closing coil current time curve, opening coil current time curve and the maximum coil current
5. Test travel time curve, speed time curve and acceleration time curve
6. Measurement of pre-insertion resistance value and pre-insertion ion time.
7. Test contact resistance
8. Measurement of dynamic resistance time curve and length for arcing contacts
9. Vibration test, including vibration fingerprint curve acquisition, management, and vibration fingerprint curve automatic matching.
10. CO-t1-CO,O-t-CO-t1-CO,CO rated operating sequence verification test.
11. Drawing Envelopes for reference travel curve and compare travel curve with envelopes
12. Mechanical travel curve automatic compare with saved travel curve
13. Measurement of CO time (close-open time) and OC time (Opening-Closing time)
14. Graphite contact closing time, opening time, dynamic resistance curve measurement
Zoom, editors, statistics and analysis for measurement curves.
15. 12.1-inch touch screen for control and data input
16. Built-in micro printer for test result printout.
17. Generate WORD format test report automatically (all reports and data can be exported through Flash disk).
 
 
Main Parameter:
IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

  
Model IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Tester
12 channels for time measurement 3-channel supports both the time contact and resistance contact time
6-channel isolated contacts for cascaded unit measurement of pole
Time measurement Range: 4000ms
Error :< 0.1ms
Resolution: 0.01ms
Travel measurement according to sensor Linear resistance sensor: 
Measurement range: 0~250mm; resolution: 0.01mm; error:<0.5mm
Measurement range: 0~25mm; resolution: 0.01mm; error:<0.05mm
Angle resistance sensor:
Measurement range: 0~360°; resolution: 0.01°; error:<0.5°
Pre-insertion Resistance Measurement Range: 50~5000ohm; error :<1%RDG+2D
Dynamic resistance measurement Test current: 25~100A
Measurement error :< 1%RDG+2D
Contact resistance measurement Range:0--10mohm ; Error<0.5%RDG+0.05%FS
Range: 0-2mohm; Error:<0.5%RDG+2D
Speed measurement 250mm linear resistance scale: 0~20m/s; error:<0.5%RDG+2D
25mm linear resistance scale: 0~20m/s; error:<0.5%RDG+2D
Angle sensor: 0~20m/s; error:<0.5%RDG+2D
Acceleration sensor: 0~20m/s; error:<5%RDG+2D
Coil current measurement Range: 0~20A; resolution: 0.001A; error:<0.01A
Vibration measurement Range: 0~5000G; error:<3%
Internal DC power source Voltage: 12~265V; current:0~20A
Data Save Built-in 8G storage memory and 2 USB interface for data export and external keyboard or mouse connection
Power supply AC220V±10%; 50Hz±10%
Working environment Temperature: -10~50°C; Humidity:<80%

IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker AnalyzerIEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer
IEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker AnalyzerIEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker AnalyzerIEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker AnalyzerIEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker AnalyzerIEC62271 High Voltage Switch Breaker Opening Time Test Circuit Breaker Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters