• Current Potential Transformer Test Equipment CT PT Tester
  • Current Potential Transformer Test Equipment CT PT Tester
  • Current Potential Transformer Test Equipment CT PT Tester
  • Current Potential Transformer Test Equipment CT PT Tester
  • Current Potential Transformer Test Equipment CT PT Tester
  • Current Potential Transformer Test Equipment CT PT Tester

Current Potential Transformer Test Equipment CT PT Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Test Equipment CT PT Tester
Apparatus: Transformer Test Equipment CT PT Tester
Application: Current Transformer CT , Turn Ratio ,Polarity Test
Function: CT PT Tester, CT Vt Tester
Device: Mutli-Function CT PT Analyzer
Samples:
US$ 7000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDVA-405
Test Standards
IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C5
Power Supply
AC220V±10%, 50/60Hz±10%
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Power Output
500va
Maximum Knee Voltage Measurement
45kv
Transport Package
Standard Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
100PCS/Month

Product Description

GDVA-405 Current Potential Transformer Test Equipment CT PT Tester

Current Potential Transformer Test Equipment CT PT Tester
Current Potential Transformer Test Equipment CT PT Tester
Tests for Current Transformer:

» Excitation curve and parameters test
» Turns ratio test
» Ratio and phase error test
» Polarity mark check
» Winding resistance measurement
» Secondary loop burden measurement
» Error line curve test for protection CT
» Transient CT parameters test
» CT nameplate guess
» Saturation hysteresis loop curve measurement



Tests for Voltage Transformer:

» Turns ratio test
» Ratio error and phase angle error test
» Polarity test
» Secondary burden test
» Winding resistance test


Applications of CT/PT Analyzer:

» CT nameplate check
» CT parameters check in work burden
» CT transient parameters analysis
» CT ratio and phase error calibration
» PT routine test



CT/PT Analyzer Function and Technical Index:

» Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
» Power supply: AC220V± 10%, 50/60Hz± 10%
» Voltage output: 0.1~180V (AC)
» Current output: 0.001~5A(RMS)
» Power output: 500VA
» Maximum knee voltage measurement: 45KV
» Current measurement:
Range: 0~10A (automatically change range in 0.1/0.4/2/10A)
Error: <± 0.1%+0.01%FS
» Voltage measurement:
Range: 0~200V (automatically change range in 1V/10V/70V/200V)
Error: < ± 0.1%+0.01%FS
» Turns ratio measurement:
Range: 1~35000
1~2000 error<0.05%
2000~5000 error<0.1%
5000~35000 error<0.2%
» Phase measurement: Error: ± 2min; Resolution: 0.01min
» Winding resistance measurement:
Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error: < 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
» Temperature measurement: -50~100 Celsius degree; Error<3 Celsius degree
» CT Secondary burden:
Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.001ohm
» PT Secondary burden:
Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error: <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
» PT ratio measurement:
Range: 1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
» PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
» PT phase angle measurement: Maximum error < 3min
» Make evaluation for test results according to selected standards
» Make word report for test result
» Make word reports one time for multi-group test records on the PC
» Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
» Compare excitation curves with saved excitation curves in the same window
» Memory capacity: >1000 groups test results
» Working condition: Temperature: -10º C~50º C; Moist: ≤ 90%
» Size: 485mm× 356mm× 183mm
» Weight: <15kg

 
Current Potential Transformer Test Equipment CT PT Tester
Current Potential Transformer Test Equipment CT PT Tester
Current Potential Transformer Test Equipment CT PT Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters