• Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
  • Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
  • Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
  • Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
  • Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
  • Portable 5kv 10kv Insulating Resistance Test Set Megger Meter

Portable 5kv 10kv Insulating Resistance Test Set Megger Meter

After-sales Service: Yes
Warranty: 1 Year for Insulating Resistance Test Set Megger
Usage: Megger, High Voltage Insulation Resistance Test
Output Voltage: 250V, 500V, 2500V, 5000V, 10000V
Power Supply: 220V, 50Hz or Battery
Power: Electronic
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD2306
Product Name
Multi-Function Megger Insulation Resistance Tester
High Voltage Short Circuit Current
>1mA
Transport Package
Carton Case
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
1000PCS/Month

Product Description

A Megohmmeter or insulation resistance tester, also colloquially known as megger, is a special type of ohmmeter used to measure the electrical resistance of insulators.Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.

For this purpose, megohmmeters, which can provide high DC voltages (typically in ranges from 500 V to 5 kV, some are up to 15 kV) at specified current capacity, are used. Acceptable insulator resistance values are typically 1 to 10 megohms, depending on the standards referenced.

Portable 5kv 10kv Insulating Resistance Test Set Megger Meter

Operation

Resistance to be measured is connected across the terminals i.e. connected in series with the deflecting coil and across the generator. When the current is supplied to the coils then they have torque in opposite directions.

If resistance to be measured is high, no current will flow through the deflecting coil, the controlling coil, will, therefore, set itself perpendicular to the magnetic axis and hence set the pointer to the infinity.

If the resistance to be measured is small, high current flow through the deflecting coil and the resulting torque sets the pointer to zero.

For the intermediate value of resistance, depending upon the torque production, the pointer is set at a point between zero and infinity.

The hand-driven generator is of the permanent magnet type and it is designed to generate from 500 to 2500 volts. Testing voltage is produced by the rotation of the crank in a hand-operated megger, or by the battery in the case of an electronic-type megger. For testing a range up to 440V, equipment requires 550V DC is sufficient. The current coil or deflecting coil is series-connected and allows the electric current to flow through the circuit being tested.

Control and deflecting coil has a current limiting resistor connected in series so as to protect the external circuit in case of damages caused due to very low resistance. Testing voltage is produced by electromagnetic induction in case of hand-operated megger and by a battery in case of electronic type megger. The deflection of pointer increases with the increases in voltage in the external circuit and also decreases with the increase in current. That is, resultant torque is inversely related to current and directly related to voltage. While the electrical circuit that is being tested is open, the resultant torque caused due to voltage coil is maximum and the deflection pointer shows the value of 'infinity' which means the circuit does not have any shorting present and resistance is the maximum within the circuit being tested. In the case of a short circuit, the deflection pointer shows 'zero' which indicates 'no' resistance in the circuit being tested.

A Megger consists of an EMF source and voltmeter. The scale of the voltmeter is calibrated in ohms (kilo-ohms or megohms, as the case may be). In measurements, the EMF of the self-contained source must be equal to that of the source used in calibration.

 

Steps to use

Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
Portable 5kv 10kv Insulating Resistance Test Set Megger Meter


Scene Show
Portable 5kv 10kv Insulating Resistance Test Set Megger Meter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters