• Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
  • Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
  • Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
  • Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
  • Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
  • Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard

Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Three Phase Relay Protection Tester
Type: Three Phase Relay Protection Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 3500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDJB-PC
Display
Digital
Control
Manual Control
Weight
12kg
Power Source
AC220V
Production Name
Three Phase Relay Protection Tester
Test Standard
IEC60044
Application
Secondary Injection Tester
Print
Micro-Printer
Power Supply
20V, 50Hz
Time Frame
1ms-9999s
Transport Package
Veneer Case
Specification
338*168*305mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard

Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard

Product description
The GDJB-PC microcomputer relay protection tester is a new type of compact microcomputer relay protection testing instrument. It can operate independently as a standalone device or be connected to a laptop for operation. The host is equipped with a new generation of high-speed digital signal processor microcomputer, a true 16-bit DAC module, a new type of modular high-fidelity high-power amplifier, a large LCD screen display, and a flexible and convenient trackball mouse controller. With its small size, high accuracy, easy operation, high reliability, and cost-effectiveness, this instrument is a preferred choice among professionals in the field.

Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard


Can you test relays with a multimeter?
Generally, it is not recommended to measure the parameters of the secondary circuit tester with a multimeter, because the measurement range of the multimeter may not be sufficient to cover the parameter range of the secondary circuit tester, and the measurement accuracy of the multimeter may not be high enough, which may affect the accuracy of the test results.

The parameters of the secondary circuit tester include voltage, current, frequency, phase, and other values that need to be accurately measured within a certain range to ensure the stability and safety performance of the power system. Therefore, it is recommended to use dedicated secondary circuit testers for testing and calibration.

If a dedicated secondary circuit tester is not available, calibrated electronic test instruments such as digital multimeters, oscilloscopes, and others can be considered for measurement. However, before using any test instrument for measurement, it is important to carefully read the instructions for the test instrument and follow the operating procedures outlined in those instructions to avoid erroneous measurements and improper operation that could result in equipment damage or safety accidents.

Rated parameters

No. Items Specifications
Alternating Current(AC) output
1 Output accuracy 0.5magnitude
2 Phase current output (effective value) 0~40A
3 Three parallel phase current output (effective value) 0~120A
4 Phase current value with long time under permission (effective value) 10A
5 Phase current maximum power output 420VA
6 Three parallel phase current maximum power output 900VA
7 Three parallel phase current maximum work time 10s
8 Frequency range (base wave) 20~1000Hz
9 Harmonic frequency number 1~20 time
Direct Current(DC) output
1 Output accuracy 0.5magnitude
2 Current output 0 ~ ± 10 A/each phase
0 ~ ± 30 A/every three parallel
3 Maximum output of load voltage 20v
Alternating Voltage output
1 Output accuracy 0.5magnitude
2 Phase voltage output (RMS) 0 ~ 120v
3 Line voltage output (RMS) 0 ~ 240v
4 Phase voltage/line voltage power output 80VA/100VA
5 Frequency range (base wave) 20 ~ 1000Hz
6 Harmonic frequency number 1 ~ 20 times
Direct voltage output
1 Output accuracy 0.5magnitude
2 Phase voltage output amplitude 0 ~ +160v
3 Line voltage output amplitude 0 ~ + 320v
4 Phase voltage/line voltage power output 70VA/140VA
The switch quantity and time measurement
1 Switch parameters input 7 ways;
Empty contact: 1~20mA, 24v
Power contact access: "0":0~ +6V;  
"1":+11 V ~ +250V
2 Switch parameters output 2 couples  DC:220V/0.2A;   AC:220V/0.5A
3 Time measurement Measuring range: 0.1ms ~ 9999s / 0.1ms


Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
 

Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard
Three Phase Relay Protection Tester Secondary Injection Test Set with High Standard

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters