Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Transformer Tan Delta Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
  • Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
  • Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
  • Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
  • Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
  • Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
GDGS
Auto./Manual
Fully-Automatic
Interference Ratio
Interfrence Current Is No More Than 2 Times of The
PF Range
No Limit, Resolution 0.001%, C/L/R Specimen Test
Input Current Range
10μa~1A
Internal Hv
0.5~10kv/200mA(Max)
Hv Accuracy
±(Reading*1%+10V) Resolving 1V
Frequency Select
60Hz Single Point, Locked; 55Hz/65Hz Double Point,
Test Time
40s Typical
Power Supply
180V~270V 50Hz/60Hz Auto
Dimention
550*490*580mm
Transport Package
Standard Wooden Case
Specification
550*490*580mm
Trademark
GOLD
Origin
China
HS Code
9030849000
Production Capacity
1000 Sets / Month

Product Description

Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus

Product Description

 

  1. It is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;
  2. It can also supply high voltage source for testing;
  3. Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency.
  • Specifications:
Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
Item Name GDGS Automatic Transformer Power Factor Tester
Use Condition -15 ºC ~ 40 ºC RH<80%
Anti-interference Frequency Conversion
Power AC 220V ± 10% Allowable Generator
High Output 0.5 kV ~ 10 kV every 0.1 kV
Precision 2%
Maximum Current 200A
Capacity 2000VA
Self-excited Power AC  0V-50V/15A 45HZ/55HZ   47.5HZ/52.5HZ
55HZ/65HZ   57.5HZ/62.5HZ
Automatic Double Frequency
Resolving Power tgδ: 0.001% Cx: 0.001pF
Precision Δtgδ: ± ( Reading*1.0%+0.040% )
ΔCx : ± ( Reading*1.0%+1.00PF )
Measuring Range tgδ Unlimited
Cx 15pF<Cx<300nF
  10kV Cx < 60 nF
  5kV Cx < 150 nF
  1 kV Cx < 300 nF
CVT Test Cx < 300 nF
CVT Range 10 ~ 10000
Accuracy 0.10%
Resolving Power 0.01
Exterior Dimension 350(L)×270(W)×270(H)
Memory Size The 200 Group Supports U Disk Data Storage
Weight 28Kg
  • Product Show:
Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus
Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus

Host of GDGS Transformer Tan Delta Tester                                                Accessory box for GDGS Transformer tan delta tester

Company Profile

Power Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test ApparatusPower Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test ApparatusPower Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test ApparatusPower Factor Tester Transformer Tan Delta Test Instrument Dielectric Loss Test Apparatus

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier