• Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
  • Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
  • Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
  • Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
  • Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
  • Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

After-sales Service: Life Time Support Service
Warranty: 1 Year for Transformer Dielectric Loss Tan Delta
Type: Transformer Dielectric Loss Tan Delta Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 2500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGS
Display
Digital
Control
Manual Control
Weight
28kg
Power Source
AC220V
Product Name
Transformer Dielectric Loss Tan Delta Tester
Power Supply
AC220V±10 % 50Hz/60Hz
Internal Hv
0.5~10kv
Input Current Range
10μa~1A
Condition of Use
-5°c~40°c, Rh<80%
Frequency of Self-Excited Power
45Hz /55Hz
Maximum Current of Self-Excited Power
15A
Maximum Output Capacity
200mA
Transport Package
Standard Wooden Case
Specification
550*490*580mm
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
50PCS/Month

Product Description

Automatic Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

Introduction:

  • Automatic Transformer Dielectric Loss Tan Delta Tester Power Factor Meter is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

  • It can also supply high voltage source for testing.

  • Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency;

  • Automatic Transformer Dielectric Loss Tan Delta Tester Power Factor Meter can also use generator as power supply;

  • If equipped with a insulation oil vessel and a temperature detector, it can also measure tan delta of insulation oil;


Specifications:

No. Item Name Automatic Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
1 Use conditions -15ºC∽40ºC RH<80%
2 Anti-interference Frequency conversion
3 Power AC 220V±10% Allowable generator
4 High output 0.5KV∽10KV Every 0.1kV
Precision 2%
Maximum current   200mA
Capacity 2000VA
5 Self-excited power AC 0V∽50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6 Resolving power tgδ: 0.001% Cx: 0.001pF
7 Precision △tgδ:±(Reading*1.0%+0.040%)
△C x :±(Reading*1.0%+1.00PF)
8 measuring range tgδ Unlimited
C x 15pF < Cx < 300nF
  10KV Cx < 60  nF
   5KV Cx < 150 nF
   1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT range 10∽10000  
accuracy 0.1%  
Resolving power 0.01  
10 Exterior dimension 350(L)×270(W)×270(H)  
11 Memory size The 200 group supports U disk data storage  
12 Weight 28 Kg  

Product Details:

Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

Success Case:
Transformer Dielectric Loss Tan Delta Tester Power Factor MeterTransformer Dielectric Loss Tan Delta Tester Power Factor Meter
Transformer Dielectric Loss Tan Delta Tester Power Factor Meter
Customers Visit:
Transformer Dielectric Loss Tan Delta Tester Power Factor Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters