• Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
  • Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
  • Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
  • Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
  • Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
  • Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment

Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Oil Bdv Tester
Type: Power Factor Tester Dielectric Loss Tan Delta Test
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 4200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Specifications
  • Test Results
  • Similar Products
Overview

Basic Info.

Model NO.
GDMZ
Display
Digital
Control
Manual Control
Power Source
AC220V
Oil Cylinder Position
Under
Apparatus
Power Factor Tester Dielectric Loss Tan Delta Test
Application
Automatic Transformer Tan Delta Tester
Function
Capacitance Measuring,Dissipation Factor Tester
Device
Capacitance and Tan Delta Dissipation Tester
Capacitor Value
1%Rdg+5PF
Tangent Delta
1%Rdg+0.04%
Output Voltage
AC 0.5kv~10kv
Testing Voltage Setting Resolution
0.5kv
Maximum Output Capacity
200mA
Testing Frequency
45Hz/55Hz
Transport Package
Wooden Case
Specification
ISO Certificate
Trademark
GOLD
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
200PCS/Month

Product Description

Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment

 
Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
 
Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
 
 

Product Description

1. GDMZ Precision Capacitance and Tan Delta Dissipation Tester is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test.


2. GDMZ Precision Capacitance and Tan Delta Dissipation Tester is whole in one designed: including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits. It's also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it's running automatically and then outputs the results on LCD display and prints the results automatically.
 
 

Specifications

 

1 Condition of Use -5°C~40°C, RH<80%
2 Power Source AC 110V±10%  Without Frequency Limit

3

High Voltage Output
Range:1KV~10KV, every 1KV
Precision:5%
Maximum Current:140mA
Capacity:1000VA

4

Self-Excited Power
Voltage Range:AC0-30V
Frequency:45Hz/55Hz
Maximum Current:15A

5

Definition
tgδ: 0.001% ; Cx: 0.1PF

6

Accuracy
tgδ:±(reading*1.0%+0.040%)
Cx:±(reading*1.0%+1.0pF)
7 Measuring Range tgδ: Without Limit
Cx:15pF<Cx<100000pF
10KV:Cx<30000pF
5KV:Cx<60000pF
1KV:Cx<100000pF
CVT Test:Cx<100000pF
8 Size 470mm(L) ×320mm(W)×390mm(H)
9 Weight 30kg

 

Test Results

Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment
Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment

Similar Products

Precision Transformer Power Factor Tester Dielectric Loss Tan Delta Test Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters