ISO 9705 Room Corner Testing apparatus fire resistant
the introduction of ISO 9705 tester:
Based on oxygen consumption principle of GB/T 25207-2010 "on the surface of material entity room burning fire test method standard is a reference to ISO 9705 the surface material full size room test writing standard of combustion test, the test method to simulate the corner fire scenario as a condition of standard test, and test the installation of the sample completely according to actual use, which is one of the most reliable standard test method.Due to the relatively complex sample quantity and test conditions required by this test, it is usually used in fire science research and to evaluate the combustion characteristics of materials that cannot be correctly evaluated by small size test.
The test equipment consists of four parts, including combustion chamber, flue gas collection and sample gas collection system, gas analysis and data processing system, and gas supply system.The test was conducted in a combustion chamber with a surface area of about 21m2 and a normally open door. The tested materials were installed in accordance with the actual usage.A right triangle sandbox burner is set at the corner and wall contact point in the room. The gas is propane gas. During the test, the gas flow should be controlled to 100kW 10 minutes before the standard heat output of the fire source.During a total of 20 minutes of test period, flashover will stop the test.The determination of the shock phenomenon can be determined by observation and the test curve of the heat release rate.
During the test, the indexes of heat release, heat release rate, smoke generation and smoke generation rate are mainly tested.
the standard we can meet for each country:
• ISO 9705 : Fire tests - Full scale room test for surface products
• ISO 13784-1: Reaction to fire tests for sandwich panel building systems
• ASTM E 1537: Standard Test Method for Fire Testing of Upholstered Furniture
• ASTM E 603: Standard Guide for Room Fire Experiments
• prEN 14390: Fire Test - Full Scale Room Test for Surface Products
• NFPA 265: Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
• NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
the specifications about this product:
Measuring Section.
- Bi-Directional Probes & DPT (Differential Pressure Transducer) for measuring flow rate in duct
- Thermocouples for measuring temperature in duct
- Sampling Port & Analyzer (O2, CO2, CO) for collecting and analyzing generated gases
- Laser used to measure the amount of smoke
Rapid cooling system (Cold Trap) used to remove moisture for analyzing pure gas
Pressure (DPT) Line for measuring flow rate and Gas Sampling for gas collection.
Filtering System for delivering reliable gases with no impurities into analyzer
Module for data collection (Data Logger, DAQ System)
PC for auto control and data monitoring
FC(Mass Flow Controller) for automatically controlling flow of propane gas.
Auto Valve System for opening/closing propane gas.
Ignition System for auto ignition
Specification: |
|
Size |
Test Room (mm) |
Power |
220V AC, 60Hz, 10A |
Exhaust |
3.5 m2/s |
Utilities |
Propane Gas Valve System, |
the main features:
Hood Skirt: Hood for collection of flue gases and prevention of flue gases of overflow.
Strainer for securing stable flow.
Suction pump for drawing gases generated in duct to the Control Lab
Test Result:
Heat Release Rate
Smoke Product Rate
Consumption and yield measurement of O2, CO and CO2
Analysis of other toxic gases (Others Toxic Gas By FT-IR)
Measurement of change in temperature of entrance