• ISO 9705 Room Corner Testing Apparatus Fire Resistant
  • ISO 9705 Room Corner Testing Apparatus Fire Resistant
  • ISO 9705 Room Corner Testing Apparatus Fire Resistant
  • ISO 9705 Room Corner Testing Apparatus Fire Resistant
  • ISO 9705 Room Corner Testing Apparatus Fire Resistant
  • ISO 9705 Room Corner Testing Apparatus Fire Resistant

ISO 9705 Room Corner Testing Apparatus Fire Resistant

After-sales Service: Yes
Warranty: 1 Year
Standard: ISO 9705, ISO 13754, ASTM E 1537, Nfpa 265, Nfpa 286
Power: 220V AC, 60Hz, 10A
Test Room: 3, 600 (W)*2, 400 (D)*2, 400 (H) 
Transport Package: Plywood Case
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-9705
Trademark
Gold
Origin
China
HS Code
9031809090
Production Capacity
10 Sets/Month

Product Description

ISO 9705 Room Corner Testing apparatus fire resistant 

ISO 9705 Room Corner Testing Apparatus Fire Resistant

the introduction of ISO 9705 tester:

Based on oxygen consumption principle of GB/T 25207-2010 "on the surface of material entity room burning fire test method standard is a reference to ISO 9705 the surface material full size room test writing standard of combustion test, the test method to simulate the corner fire scenario as a condition of standard test, and test the installation of the sample completely according to actual use, which is one of the most reliable standard test method.Due to the relatively complex sample quantity and test conditions required by this test, it is usually used in fire science research and to evaluate the combustion characteristics of materials that cannot be correctly evaluated by small size test.

The test equipment consists of four parts, including combustion chamber, flue gas collection and sample gas collection system, gas analysis and data processing system, and gas supply system.The test was conducted in a combustion chamber with a surface area of about 21m2 and a normally open door. The tested materials were installed in accordance with the actual usage.A right triangle sandbox burner is set at the corner and wall contact point in the room. The gas is propane gas. During the test, the gas flow should be controlled to 100kW 10 minutes before the standard heat output of the fire source.During a total of 20 minutes of test period, flashover will stop the test.The determination of the shock phenomenon can be determined by observation and the test curve of the heat release rate.  

During the test, the indexes of heat release, heat release rate, smoke generation and smoke generation rate are mainly tested.

the standard we can meet for each country:

• ISO 9705 : Fire tests - Full scale room test for surface products 
• ISO 13784-1: Reaction to fire tests for sandwich panel building systems 
• ASTM E 1537:  Standard Test Method for Fire Testing of Upholstered Furniture 
• ASTM E 603:  Standard Guide for Room Fire Experiments 
• prEN 14390: Fire Test - Full Scale Room Test for Surface Products 
• NFPA 265: Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls 
• NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

the specifications about this product:
Measuring Section. 
- Bi-Directional Probes & DPT (Differential Pressure Transducer) for measuring flow rate in duct 
- Thermocouples for measuring temperature in duct 
- Sampling Port & Analyzer (O2, CO2, CO) for collecting and analyzing generated gases 
- Laser used to measure the amount of smoke 
Rapid cooling system (Cold Trap) used to remove moisture for analyzing pure gas 
Pressure (DPT) Line for measuring flow rate and Gas Sampling for gas collection. 
Filtering System for delivering reliable gases with no impurities into analyzer 
Module for data collection (Data Logger, DAQ System) 
PC for auto control and data monitoring 
FC(Mass Flow Controller) for automatically controlling flow of propane gas. 
Auto Valve System for opening/closing propane gas. 
Ignition System for auto ignition 

Specification:

Size

   Test Room (mm) 
   3,600 (w) × 2,400 (d) × 2,400 (h) 

   Hood  (mm) 
   3000 (w) × 3000 (d) × 2950 (h) 

   Sandbox Burner (mm) 
   170 (w) × 170 (d) × 145 (h)

Power

   220V AC, 60Hz, 10A

Exhaust

   3.5 m2/s

Utilities

   Propane Gas Valve System,
   Ignition System

the main features:
Hood Skirt: Hood for collection of flue gases and prevention of flue gases of overflow. 
Strainer for securing stable flow. 
Suction pump for drawing gases generated in duct to the Control Lab

Test Result:
Heat Release Rate 
Smoke Product Rate 
Consumption and yield measurement of O2, CO and CO2 
Analysis of other toxic gases (Others Toxic Gas By FT-IR) 
Measurement of change in temperature of entrance 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters