  • IEC 60112 Stainless Steel Tracking Index Tester
  • IEC 60112 Stainless Steel Tracking Index Tester
  • IEC 60112 Stainless Steel Tracking Index Tester
  • IEC 60112 Stainless Steel Tracking Index Tester
Find Similar Products

Basic Info.

Model NO.
GD-IEC60112
Standard
IEC 60112
Electrode Material
Electrode Tip - Platinum Metal (Platinum)
Electrode Pressure
1.0 +-0.05n
Electrode Voltage
100 ~ 600V (48 ~ 60Hz) Adjustable, Short-Circuit C
Dropping Height
for 30 ~ 40mm Adjustable
Dropping Size
44 ~ 55 Drops / 1cm3 Adjustable
Dropping Time
30s+-5s,
Dropping Times
0 ~ 9999 Times Available
Transport Package
Plywood Case
Trademark
GOLD
Origin
China
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

IEC 60112 Stainless Steel Tracking Index Tester
 

Introduction:

The tracking tester is in strict accordance with GB4207, and IEC60112 standards for design and manufacture. It is suitable for lighting, low-voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment, and electrical instruments. It also applies to the insulation, plastic, electrical connectors, and accessories industry. Method for the determination of the proof and the comparative tracking indices of solid insulating materials. It has simple, accurate, reliable, and practical features.

Standard:

GB/T4207,GB4706.1 ASTM D 3638-92,IEC60112 ,UL746A 

Feature:

1.The combustion chamber paint treatment; nice, corrosion-resistant; dimensions: 1200mm X 600mmx 1200mm;

2. All sample holders are made of stainless steel manufacturing;

3. The device consists of a voltmeter, ammeter, time overcurrent relays, power supplies, circuit control system, push button switches, lights and other components;

4. Automatic drip device includes dropping tube, drip nozzle, counting means counting device drip, drip control device, dropping the volume measuring tools;

5. The drip nozzle device can be adjusted; adjust the height of 30-40mm; ensure the dripping position in the middle of the two electrodes;

6. The electrode means comprises a platinum electrode, the electrode fixtures, 4mm gauge, etc., the electrode can be adjusted, and removable;

7. Electrode width 5mm, thickness 2mm, 99.9% purity platinum, 30 to 60 degrees tip;

8. The electrode sample pressure is adjustable, adjustable range (1.00N ± 0.001N); the electrode distance is 4.0mm ± 0.01mm, the angle 60 ° ± 5 °;

9. With the sample stage;

10. With the glass: Thickness ≥4mm;

11. With electrolyte: sodium chloride and alkyl naphthalene sulfonic acid reagent in each bottle.

Safety control system:

1. The test voltage: 0 ~ 1000V adjustable

    The maximum error of voltmeter displays: 1%;

2. Short-circuit current: (1 Guests 0. 1) A,

   The voltage drop value does not exceed 10%

3. The test current exceeds 0.5A more than two seconds, the system automatically shuts down equipment;

4. Security door control system; the door opens, but the test system is not working;

5. The electrode: 5mm × 2mm rectangular platinum electrode and brass electrode of each pair meet size requirements of IEC60112 Figure B.1;

6. The electrode: the angle formed between the electrodes is 60 ° disabilities 5 °, a pitch of (4 Soil 0.1mm);

7. The electrode: the sample pressure: 1 00N disabilities 0.05N;.

8. Drip system: (30 ± 5) seconds (on time 29.8S + open drip duration 0.2S) automatic counting, digital display (can be preset), 50 drops of time: (24.5 Soil 2) min;

9. Drip systems: a drop of the fluid needle tip to the sample surface height: 35mm disabilities 5mm (attach a gauge for measuring your reference);

10. Drip systems: drip Weight: 20 drops: 0.380g ~ 0.489g; 50 drops:.. 0 997g ~ 1 147g;

11. PLC with touch screen control system; to achieve test smarter, more convenient has been operated.

12. The test data is automatically recorded, automatic storage, free retrieval;

Specification:

The electrode material

electrode tip - platinum metal (platinum)

The electrode pressure

1.0 ± 0.05N

Electrode distance

4.0mm ± 0.01mm, the angle 60 ° ± 5

Electrode voltage

100 ~ 600V (48 ~ 60HZ) adjustable, short-circuit current 1.0 ± 0.1A  of less than 10%

Dropping height

For 30 ~ 40mm adjustable

Dropping size

44 ~ 55 drops / 1cm3 adjustable

Dropping time

30s ± 5s,

Dropping times

0 ~ 9999 times available

The leakage judgment

when the loop current is greater than 0.5A and maintained for 2 seconds, the relay cuts off the current and the result indicates sample failed

The testing process

automatic control, independent ventilation

The reference standard

IEC60112, GB / T4207, GB4706.1

The inside Volume

0.1 m³ (Can be customized 0.5 m³ or 0.75 m³)

The outside dimensions

630mm width x390mm depth x750mm height

 
Details:
IEC 60112 Stainless Steel Tracking Index Tester
IEC 60112 Stainless Steel Tracking Index Tester
IEC 60112 Stainless Steel Tracking Index Tester

Our Company:

Since 2008, Chongqing Gold Mechanical & Electrical Equipment Co., Ltd. has developed 70 kinds of fire testing instruments and served many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection, and so on.

Our mission is to provide reliable products to our customers to meet their requirements of testing, R&D, and quality control. In addition, Gold insists on high-quality standards in niche markets and targets to minimize the gap between Chinese local products and imported products.

We work with trust, honesty, and a sense of responsibility, so quality and service are always our advantages over all competitors.
IEC 60112 Stainless Steel Tracking Index Tester
IEC 60112 Stainless Steel Tracking Index Tester
IEC 60112 Stainless Steel Tracking Index Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier