CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for IEC 61869 CT Analyzer
Still deciding? Get samples of US$ 8200/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
  • CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
  • CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
  • CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
  • CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
  • CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
GDVA-405 CT PT Analyzer
Application 3
Comprehensive Characteristic Test of CT PT
Reference Standards 1
IEC60044-1, IEC60044-6, IEC61869,IEC60044-2
Reference Standards 2
IEC60044-5, IEEE Std C57.13-2016 and So on
Operation Mode
Automatic Testing
PC Control
Yes(Optional)
Max. Knee Voltage
60kv
Transport Package
Plywood Case for IEC 61869 CT PT Analyzer
Specification
net weight 20kg for GDVA-405 CT PT Analyzer host
Trademark
IEC 61869 CT PT Analyzer
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
100PCS/Month

Product Description

CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
          Host of GDVA-405 IEC 61869 CT PT Analyzer                                             Accessories of GDVA-405 CT PT Analyzer
 
Product Description

Brief Introduction of GDVA-405 CT PT Analyzer IEC 61869:

1)GDVA-405 Automatic CT PT Analyzer is the powerful testing system for various CTs and PTs according to standards IEC61869-2 (IEC 60044-1, IEC 60044-6), IEC61869-3 (IEC60044-2) and IEEE Std C57.13-2016.
GDVA-405 CT Analyzer can automatically complete the test within seconds by one click "Run test" of 12 inch touch screen.
It allows to test the knee-point voltage up to 60kV CTs and PTs on-site in power grids or in manufacturers' production facilities or test laboratories.
 
The host of GDVA-405 Automatic CT PT Analyzer is only 15kg. which is easy to carry on testing site. We will also provide free aluminum alloy suitcase for easy mobility and transportation


Available Test Standards by GDVA-405 CT PT Analyzer:

1) IEC60044-1
2) IEC60044-6,
3) IEC61869,
4) IEC60044-2,
5) IEC60044-5,
6) IEEE Std C57.13-2016 and others




How to performance the CT Ratio and Phase Angle Error test by our GDVA-405 IEC 61869 CT PT Analyzer?

CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869
1) Connect the GDVA-405 Automatic CT PT Analyzer with sample CT according to reference wiring diagram in the upper right corner of the screen.
Normally, S1 connect with yellow and green wire, S2 connect with black and black wire, P1 connect with red wire, P2 connect with black wire.
2) Click "CT ratio and phase angle" button in "wait for new test" state.
3) Set parameters for "CT ratio and phase angle" test.
4) Run test after clicking start button.
5) Wait for the end of "CT ratio and phase angle test".
6) Analysis test results.

Test Results by GDVA-405 IEC61869 CT PT Analyzer as following:

CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869


The following test items can be tested by GDVA-405 CT PT Analyzer 
(If the tests you need to complete are not included in the testing items listed below, please contact us for customization):

 
Test items for Current Transformer(CT) Test items for Potential Transformer(PT)

1) Turn ratio detection

2) Ratio and angle error check

3) Polarity test

4) Excitation characteristic test

5) Secondary winding resistance measurement and secondary burden measurement

6) 5% and 10% error curve measurement

7) Transient characteristics analysis

8) Automatic nameplate inference

9) Knee point voltage/current

10) Accuracy Limit Factor (ALF)

11) Instrument security factor (FS)

12) Secondary time constant (Ts)

13) Remanence coefficient (Kr)

14) Accuracy

15) Saturation and desaturation inductance

16) Knee point electromotive force

17) Limit electromotive force

18) Area factor

19) Iron core analysis and core hysteresis loop measurement

1) Turn ratio measurement

2) Ratio and angle error check

3) Polarity test

4) Excitation characteristic test

5) Primary winding resistance test

6) Secondary winding resistance test

7) Secondary burden measurement


Product Parameters

Power Supply
AC220V±10%, 50/60Hz±10%(Support customize to AC110V,120V,127V).

Output
 
Current Output 0.001-5A(RMS)
Voltage Output 0.1-180V (AC)
Power Output  500VA
 
Current measurement

range: 0-10A (automatically change  range in 0.1/0.4/2/10A).

Error:<±0.1%+0.01%FS.

Voltage measurement

range: 0-200V (automatically change range in 1V/10V/70V/200V).

error: < ±0.1%+0.01%FS.

Turns ratio measurement Range 1-35000
1-2000, error<0.05%
2000-5000,error<0.1%
5000-35000,error<0.2%
Phase measurement

error: ±2min;

resolution:  0.01min

Winding resistance measurement

range: 0-8kΩ
(automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm).

error: < 0.2%RDG+0.02%FS.

Maximum resolution :  0.1mΩ.

Temperature measurement -50-100 ºC; error<3ºC.
CT Secondary burden

Range: 0-80kohm
(automatically change range in 800ohm/8kohm/80kohm).

error: <0.2%RDG+0.02%FS.

Maximum resolution : 0.1ohm.

PT ratio measurement range

1-35000,

1-10000 error<0.1%,

10000-35000 error<0.2%

PT ratio measurement error

Typical error<0.05%,  Maximum Error<0.1%.

equip with PT Booster Comparator(Optional), the accuracy can reach 0.05%.


CT Ratio and Phase Angle Error Testing Equipment Automatic CT PT Analyzer IEC 61869