Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus

Product Details
Customization: Available
Power Source: AC220V
Product Name: Low Temperature Flash Point Test Apparatus
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
  • Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
  • Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
  • Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
  • Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
  • Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
Find Similar Products

Basic Info.

Model NO.
GD-5208
Standard
ASTM D93
Test Sample
Colored Paints;Oil Paints;Solvents and Petroleum
Temperature Range
-30~50 Celsius
Ignition Mode
Manual
Temperature Display
LCD
Printing
Yes
Comminication Port
No
Sample Cup
2ml
Dimension
370*280*280mm
Transport Package
Wooden Case Gd-5208
Trademark
gold
Origin
China
Production Capacity
100 Piece/Pieces Per Month

Product Description

Paints and Solvents Manual Type Rapid and Low Temperature Flash Point Test Apparatus

 


Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test ApparatusLaboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus
Summary

This Rapid and Low Temperature Flash Point Test Apparatus is designed and made as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway, aviation, electricity, commercial inspection and science research institution.
This instrument is specially suitable to determine different kinds of colored paints,oil paints, adhesives,solvents and petroleum products which the closed cup flash point is -30ºC~50ºC.The instrument is also correspond with ISO1523 and ISO3679.

I. Main technical features
1.Designed as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can realize purpose of testing closed cup flash point rapidly and at low temperature.
2.The instrument adopts semiconductor refrigeration device and external water cooling device.The size is small and cooling rate is rapid.Easy to operate.
3.Test sample needed is less.2ml for each time(4ml for solid sample and semi-solid sample)
4.The determination procedure is automatically completed except ignition.Test results can be printed automatically.


II. Main technical specifications
1.Flash point measuring range: -30ºC~+50ºC;  
2. Precision of determination:it meets the standard GB/T 5208;                       
3. Temperature resolution:±0.1ºC;  
4. Igniting device:Electric igniting gun
5. Cooling mode:Semiconductor(with cold water cycle at external connection) 
6. Igniting source: gas,LPG(or other civilian fuels)
7. Power supply:AC(220±10%)V,50Hz
8. Total power consumption:<=300W;
9. Ambient temperature:5ºC~30ºC             
 Relative humidity:(30~80)%
10. Dimension:490mm×520mm×390mm
11. Net weight: 25.5kg.
 
More Closed Cup Flash Point Apparatus

Model

GD-261

GD-261-1

GD-261A

GD-261D

GD-5208

GD-5208A

Standard

ASTM D93

ASTM D93

ASTM D93

ASTM D93

ASTM D3934

ASTM D3934

Range

ambient~30°C

ambient~25°C

ambient~2°C

ambient~3°C

-30~50°C

50~100°C

Repeatability

≤2°C

≤2°C

Flash point≤104°C,

error: 2°C

Flash point>104°C,

error: 6°C

≤2°C

<2°C(same operator)

<3°C(different operators)

Reproductivity

≤4°C

≤4°C

Flash point≤104°C,

error :4°C

Flash point>104°C,

error:8°C

≤4°C

Automatic up/down

N

N

Y

Y

N

N

With micro printer

N

Y

Y

Y

Y

Y

Display

N

N

Y

Y

Y

Y

Communication port

N

N

N

Y

N

N

 

Sample

 

Standard oil cup

 

Standard oil cup

 

Standard oil cup

 

Standard oil  cup

 

2ml

 

2ml



Company  Information:

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

We mainly design and manufacture the petroleum testing instrument  
After several years' development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of petroleum testing instrument .
Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus

Laboratory Equipment Paints and Solvents Rapid and Low Temperature -30~100celsius Flash Point Test Apparatus

Contact Information:

If you have interest, please feel free to contact with me:
Chongqing Gold Mechanical&Electrical Equipment Co., Ltd
website: chinainstrument.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier