ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test

Product Details
Customization: Available
After-sales Service: on-Line and off-Line Service
Warranty: 2 Years
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test
  • ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test
  • ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test
  • ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test
  • ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test
  • ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test
Find Similar Products

Basic Info.

Model NO.
GD-4508G-1
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Type
Universal Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Oil Cylinder Position
Under
Test Standard
ASTM D6084 Ductilometer
Bitumen Test
Ductility and Elastic Recovery of Asphalt Mixture
Ductilometer
Elastic Recovery of Bituminous Materials
Feature
It Is Multifunctional
Measurement Range
1.5m
Heating Method
Heating Tube Heating
Tensile Speed
1cm / Min, 5cm / Min
Transport Package
Plywood
Trademark
GOLD
Origin
Made in China
HS Code
9031809090
Production Capacity
100sets/Month

Product Description

ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test

ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test

Definition:
Ductility is the ability of a material to undergo a visible enduring deformation through elongation (decreasing of cross section area). It expresses the extent to which the material can be plastically deformed without fracture. The opposite material behavior is brittleness. 
The test for elastic recovery is applicable to binders modified with elastomers and serves to demonstrate the modification of the binder. The sample is stretched at a fixed temperature and speed to a maximum of 20 cm and then severed. After a prescribed period of time, the degree of elastic recovery is determined relative to the original length.




Reference Standard:
1. GB/T 4508 "Standard Test Method for Ductility of Bitumen".
2. T 0605-2011 "Standard Test Method for Ductility of Bituminous Materials" in JTG E20-2011 "Application Handbook of Standard Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering".
3. NB/SH/T 0814 "Force Ductility Test of Bituminous Materials."
4. NB/SH/T 0737 "Standard Test Method for Elastic Recovery of Asphalt Materials by Ductilometer."
5. T 0662-2000 "Standard Test Method for Elastic Recovery of Asphalt Materials by Ductilometer" in "Application Handbook of Standard Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering".
6. ASTM D113-17 "Standard Test Method for Ductility of Asphalt Materials". ASTM D6084-06 "Standard Test Method for Elastic Recovery of Asphalt Materials by Ductilometer".


Key Features:
1. This instrument is multi-purpose, it is a multifunctional asphalt tester integrating asphalt ductility test, asphalt force-ductility test and asphalt elastic recovery test.
2. It adopts industrial control touch screen, advanced technology which can achieve data transmission function.
3. The novel tension transmission design adopts the combination of imported screw and guide rail. The stretching process is smooth and synchronous, no ditter, uniform speed, the ductility and tensile force are precisely displayed.
4. It adopts high-power compressor refrigeration, shielded cold and heat balance pressurized circulation system, fast cooling speed and uniform bath temperature.
5. It can do the tensile test, force test and elastic recovery test of 3 samples at a time.
6. The average ductility value, the maximum tensile force, and the elongation deformation value at the maximum tensile force are automatically calculated and displayed.
7. The designed two-layer structure of the ductility water bath was granted a national patent, the Patent No. is ZL201821604657.9.


Main Parameters:
1. Working power: AC (220 ± 10%) V, 50Hz
2. Measurement range: 1.5m (±10mm)
3. Heating method: heating tube heating
4. Heating power: 4500W
5. Bath liquid circulation: cold and heat balance circulation system
6. Temperature control range: 5ºC ~ 50ºC adjustable, digital display, temperature display resolution 0.01ºC
7. Temperature control accuracy: ± 0.1ºC
8. Tensile speed: 1cm / min, 5cm / min two files
9. Measurement accuracy: ± 1mm
10. Ductility display: industrial control touch screen real-time display
11. Ductility record:  (1) Record by hand-held remote control button                                      
                                 (2) Record by industrial control touch screen "record" button
12. Force measurement range: (0~300)N
13. Force measurement accuracy: ± 1N
14. Display resolution: 0.1N
15. Tensile force display: industrial control touch screen real-time display
16. Data output: industrial control touch screen real-time display, integrated data upload
17. Refrigeration form: 1.25HP compressor refrigeration, input power 950W
18. Ambient temperature: 15ºC ~ 35ºC
19. Relative humidity: ≤85%
20. Dimensions: 2370mm*530mm*950mm
21. Overall Power Consumption: ≤ 5600W



Welcome to visit us!

ASTM D6084 Auto Ductilometer for Elastic Recovery of Asphalt Materials Test




 