After-sales Service: | Life Time Support Service |
---|---|
Warranty: | 1 Year for DC High Voltage Generator |
Type: | DC High Voltage Generator DC Hipot Test Set |
Accuracy Grade: | 1 |
Load Way: | Electronic Load |
Loading Method: | Dynamic Load |
Customization: |
---|
Suppliers with verified business licenses
Power | AC220V+10%, 50Hz+1% |
Output voltage indicator accuracy | <1% |
Output current indicator accuracy | <1% |
Ripple contain factor | <0.5% |
0.75 times output voltage indicator accuracy | <1%, can be locked |
Model | ZGF-60/2 | ZGF-120/2 | ZGF-120/5 | ZGF-200/2 | ZGF-300/2/3 | |
Output Voltage | 60kV | 120kV | 120kV | 200kV | 300kV | |
Output Current | 2mA | 2mA | 5mA | 2mA | 2mA/3mA | |
Output Power | 120W | 240W | 600W | 400W | 600W/900W | |
Double Voltage Unit Size | 145*500mm | 145*800mm | 145*800mm | 145*1000mm | 145*1300mm | |
Operating Unit Size | 360*260*245mm | |||||
Total Weight | 10kg | 15kg | 17kg | 20kg | 25kg | |
Riple Coefficient | Less than 0.5% |
Split design, high and low voltage are completely separated, the metal shell is grounded, the high-voltage terminal is built in, there is no high-voltage or low-voltage wiring outside, the wiring is convenient, and the absolute safety of the test personnel is ensured;
The test voltage is continuously adjustable from 0 to the maximum output voltage, which can be used as a laser power supply, and can also be used in electrostatic spraying, electrostatic velvet and other occasions;
High reliability, high-frequency voltage uses multiple rectifiers, the circuit is simple, the overload capacity is strong, there are few faults, and no maintenance is required.
Small size. one person can carry the world's largest DC high-voltage generator (200kV/2mA), and its volume is only 1/(2~5) of similar equipment in Japan, reaching the international advanced level.
The metal shell has good sealing, high mechanical strength, and the performance is not affected by vibration, moisture, dust and meteorological conditions.
Multiple protections prevent overvoltage and breakdown discharge from damaging the instrument during the test. The automatic protection function is good, the high-voltage output knob cannot be turned on when it is not in zero position, the operation is simple, and the overvoltage and overcurrent will automatically stop. Built-in damping resistor, no external damping resistor is required.
High accuracy. the leakage current on the high-voltage side is measured by a digital meter with an accuracy of 1uA, no range switching is required, and the low-voltage side has a discharge withstand current measurement function, using precision resistors, good stability, and can measure high voltage.More details
Suppliers with verified business licenses