• Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
  • Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
  • Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
  • Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
  • Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
  • Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer

Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer

After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Transformer Tan Delta Tester
Type: Transformer Tan Delta Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 2600/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGS
Display
Digital
Control
Computer Control
Weight
30kg
Power Source
220V(Support Customize 110V/120V)
Product Name
Transformer Tan Delta Tester
Application
Tan Delta Test for Hv Transformer,Generator,Cable
Max Output Voltage
10kv( Support Customize 12kv)
Max Output Current
200mA
Max Output Capacity
2000va
CVT Range
10∽10000
Measuring Range
15PF < Cx <300NF
Tan Delta Value
Unlimited
Transport Package
Plywood Case for Transformer Tan Delta Tester
Specification
550*490*580
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
500 Pieces/Month

Product Description

Automatic Power Transformer Transformer Tan Delta
Capacitance and Dissipation Factor Tester with Micro Printer 

Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
1) GDGS Automatic Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer is a high-precision instrument, which can be applied to measure electrical loss tangent and capacitance of all kinds of high voltage electrical equipment in power plants, substations, laboratory, etc.

2) GDGS Automatic Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

3) It can also supply high voltage source for testing.

4) Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency;

 

Specifications

 
No. Item Name GDGS Automatic Transformer Power Factor Tester
1 Use conditions -15ºC∽40ºC RH<80%
2 Anti-interference Frequency conversion
3 Power AC 220V±10%  
4 High output 0.5KV∽10KV Every 0.1kV
Precision 2%
Maximum current   200mA
Capacity 2000VA
5 Self-excited power AC 0V∽50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6 Resolving power tgδ: 0.001% Cx: 0.001pF
7 Precision △tgδ:±(Reading*1.0%+0.040%)
△C x :±(Reading*1.0%+1.00PF)
8 measuring range tgδ Unlimited
C x 15pF < Cx < 300nF
  10KV Cx < 60  nF
   5KV Cx < 150 nF
   1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT range 10∽10000  
accuracy 0.1%  
Resolving power 0.01  
10 Exterior dimension 350(L)×270(W)×270(H)  
11 Memory size The 200 group supports U disk data storage  
12 Weight 28 Kg  

Characteristics

1) The instrument uses the complex current method to measure capacitance, dielectric loss and other parameters. The test result has high precision, which is convenient for automatic measurement.

2) The instrument adopts frequency conversion technology to eliminate 50Hz power frequency interference on site, and reliable data can be measured even in the environment of strong electromagnetic interference.

3) The instrument adopts a large-screen LCD display, and the test process is intuitive and easy to operate through English character menu prompts.

4) The instrument is easy to operate and the measurement process is controlled by the microprocessor. As long as the appropriate measurement method is selected, the data measurement can be automatically completed under the control of the microprocessor.

5) Integrated model with standard capacitor and high voltage power supply, which is convenient for on-site testing and reduces on-site wiring.

6) The instrument has high measurement accuracy and can meet the requirements of oil dielectric loss measurement. Therefore, only a standard oil cup and a dedicated test line are needed to achieve oil dielectric loss measurement.

7) With CVT test function, it can realize CVT self-excitation method test, no external accessories are needed, only one measurement is required, and capacitance and dielectric loss of C1 and C2 are all measured.

8) The reverse wiring test adopts ivddv technology, which eliminates the phenomenon that the reverse wiring data is unstable in the past.

9) With reverse wiring low-voltage shielding function, in the case of 220kVCVT busbar grounding, C11 can be measured without disconnecting 10kV reverse wiring dielectric loss

10) It has the function of measuring high-voltage dielectric loss, and can use high-voltage transformers or series resonance to conduct dielectric loss tests over 10kV.

11) Ground protection function, when the instrument is not grounded or the ground is poor, the instrument does not enter the normal procedure and does not output high voltage. Overcurrent protection function, the instrument is not damaged when the test product is short-circuited or broken down.

12) Electric shock protection function, when the instrument operator accidentally gets an electric shock, the instrument will immediately cut off the high voltage to ensure the safety of the test personnel.


Success Case
 
Philippines Customer Inspection Our GDGS Transformer Tan Delta Tester

Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer

Product Details

Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro PrinterTransformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer
 
Transformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro PrinterTransformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro PrinterTransformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro PrinterTransformer Tan Delta/Capacitance and Dissipation Factor Tester with Micro Printer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now