• ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
  • ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
  • ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
  • ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
  • ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
  • ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide

ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide

After-sales Service: Online and Offline Service
Warranty: 2 Year
Power: Electronic
Usage: Salt Content Analyzer
Purpose: Determine Total Amount of Halides in The Crude Pet
Test Standard: ASTM D3230
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Main Technical Features
  • Product Parameters
  • Main Structure
  • Matters Attention
  • Detailed Photos
  • Packaging & Shipping
  • Contact us
Overview

Basic Info.

Model NO.
GD-6532
Measuring Range
0.002% to 0.02%
Condition
New
OEM Supply
Yes
Heating Power of Extractor
300W
Power of Pressure Regulator
600W
Power Source
AC220V
Price
Low Price
Weight
0-100kg
Transport Package
One Full Set in One Wooden Box with Foam to Protec
Specification
540mm*220mm*760mm
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9013809000
Production Capacity
100 Set/Sets Per Month

Product Description

ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02%(weight) Total Halide
ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide

Product Description

GD-6532 CRUDE OIL SALT CONTENT TESTER is designed and manufactured in accordance with the requirements of the People's Republic of China standard GB/T6532 "Crude oil and its Products salt content determination Method", suitable for the determination of crude oil, top crude oil, cracking residue and fuel oil concentration of 0.002~0.02%(weight) of the total halide. It can also be used to judge the used turbine oil and Marine fuel oil pollution by sea water. When the required precision is not greater than the range specified in this method, it can also be used for other products.

Main Technical Features

1 GD-6532 Salt Content Analyzer is desktop structure. It is composed of main unit, control chamber and thermoregulation electric furnace. The main unit and control chamber are connected by a wire. The design is reasonable. Easy to use.
2 Main parts of extractor: 500ml flask (with heating wire and plug), condenser, dropping funnel can meet requirements of standard GB/T 6532.

Product Parameters

1 Extractor  As per standard GB/T 6532
2 Heating power of extractor  300W
3 Power of pressure regulator 600W
4 Power supply AC(220±10)V,50Hz
5 Dimension of main unit 540mm*220mm*760mm

Main Structure

The instrument is mainly composed of extractor (extractor) flask, heating coil, protective cover, condenser, column parting funnel (drip funnel), clamping device, digital display adjustable temperature control board, vertical rod bracket, vertical rod, double top wire, universal clip, conical flask, etc. The structure is shown on the left:

Main parts of extractor: 500ml flask (with heating wire and plug), condenser, dropping funnel can meet requirements of standard GB/T 6532.
1.The condenser     
2, universal clip    
3.Drip funnel       
4.Clamping device   
5, extractor flask   
6.Protective cover  
7, navigation       
8.Heating coil    
9. Power switch
10. Power cord
11. Voltage regulation knob
12. Digital display voltmeter
13. Power indicator
14. Pole bracket
15. Double top wire
16, stud
ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide

 

Matters Attention

Special attention: the steam generated during the test is toxic, the test should be carried out in the fume hood!
1, the power supply must be effectively and reliably grounded.
2, glass piston, grinding mouth with the best coated with appropriate grease.
3, toxic gas discharge should be carried out in the ventilation cabinet.
4, in the extractor without adding experimental solution is strictly prohibited to boot!
5, in the case of power is strictly prohibited to plug the flask!!
Warning: The power supply should be cut off immediately when the instrument fails, and professionals should be asked to repair and troubleshoot the fault before continuing to use, to prevent accidents!

Detailed Photos

ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide

 

Packaging & Shipping

ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide
ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02% (weight) Total Halide

Contact us

Welcome to contact us talk about details if you are interested in ASTM D3230 Salt in Crude Oil Analyzer of 0.002~0.02%(weight) Total Halide  !If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated !
website: chinainstrument.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters