• 0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester
  • 0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester
  • 0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester
  • 0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester
  • 0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester
  • 0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester

0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year Fortransformer Oil Bdv Dielectric Strength
Type: Transformer Oil Bdv Dielectric Strength Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Static Load
Samples:
US$ 2500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDYJ-502A
Display
7inch Colorful LCD Wih Touch Pad
Control
Manual Control
Weight
45kg
Power Source
AC220V
Oil Cylinder Position
Top
Product Name
Transformer Oil Bdv Dielectric Strength Tester
Test Standard
IEC/ASTM D
Output Voltage
AC 0~80kv/0-100kv
Rate of Voltage Rise
0.5/2/3/5 Kv/S±5%
Measuring Precision
±(1% Full Scale+2 Digits)
Test Times Setting
9
Transport Package
Wooden Case
Specification
490*410*450mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester

0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester

Why We Need Transformer Oil Insulation Strength Testing Device
 

0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester
Here are some reasons why we need a Transformer Oil Insulation Strength Testing Device:

1. To ensure the oil has sufficient breakdown voltage and insulating properties. This is crucial for the proper functioning of transformers that use the oil as insulation.

2. To detect deterioration of the oil over time due to factors like moisture absorption and contamination. This allows maintenance and replacement of the oil before failures occur.

3. To test oil quality after processing like filtration, degassing or drying. This verifies if the processing was effective in improving the oil properties.

4. To comply with standards and specifications that require testing of transformer oil characteristics. Many utilities and industries have requirements for regular oil testing.

5. To monitor the health of transformers so that issues can be identified early. A drop in oil breakdown voltage can indicate developing faults within the transformer. 

6. To provide a basis for optimization. By establishing a baseline oil quality, any improvement measures like improved oil processing can be evaluated.


What Do We Need To Be Aware of When Using The Instrument


• Ensure no air bubbles are trapped in the oil sample as these can affect the results. The oil should be degassed before testing.

• Thoroughly clean the test cell and electrodes before each test to remove any contaminants that may cause premature breakdown.  

• Allow the oil sample to settle for a few minutes before testing to release any residual dissolved gases. Agitation should be avoided.

• Use a consistent test procedure and set of parameters for comparative measurements. The test conditions must be kept uniform. 

• Calibrate the test instrument periodically as required to ensure accuracy and repeatability of the measurements.

• Where possible, record test conditions like temperature and humidity as these can influence the results.

• Use oil samples from the same source wherever feasible to detect changes in oil quality more reliably over time.

• Retain and archive all test results for future reference which is important for analyzing trends and troubleshooting issues.

• Follow the manufacturer's operating and maintenance guidelines to ensure optimum performance and reliability of the test equipment.


Introduction to Accessories

0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester

Operation Show
0-80kv Transformer Oil Bdv Insulation Dielectric Strength Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters