Automatic Dielectric Loss Tangent Test Equipment Transformer Tan Delta Tester

Auto./Manual: Fully-Automatic
Accuracy: Cx: ±(1%Rdg+5PF), PF: ±(1%Rdg+0.04)
Internal Hv: 3PF~60000PF / 10kv, 60PF~1μf / 0.5kv
External Hv: 3 PF~0.3μf / 10kv
Resolution: 0.0001PF, 4 Digital
Interference Ratio: Interfrence Current Is No More Than 2 Times of The
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGS
PF Range
No Limit, Resolution 0.001%, C/L/R Specimen Test
Input Current Range
10μa~1A
Test Time
40s Typical
Power Supply
180V~270V 50Hz/60Hz Auto
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
China
Production Capacity
1000 Sets / Month

Product Description

Automatic Dielectric Loss Tangent test equipment Transformer Tan Delta Tester 

  • Introduction:

1.It is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

2.It can also supply high voltage source for testing;

3.Frequency can be changed to 50Hz, 47.5Hz\52.5Hz,45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz; thus, it can avoid interference of power frequency.

  • Specifications:
 Automatic Dielectric Loss Tangent test equipment Transformer Tan Delta Tester 
Auto./manual Fully-automatic
Accuracy Cx: ±(1%RDG+5pF)
PF: ±(1%RDG+0.04)
Capacitance range Internal HV: 3pF~60000pF / 10kV, 60pF~1μF / 0.5kV
External HV: 3 pF~0.3μF / 10kV
Resolution: 0.0001pF, 4 digital
Interference Ratio Interfrence current is no more than 2 times of the test current
PF range No limit, resolution 0.001%, C/L/R specimen test
Input current range 10μA~1A
Internal HV 0.5~10kV/200mA(max)
HV accuracy ±(reading*1%+10V) resolving 1V
Frequency select 60Hz single point, locked
55Hz/65Hz double point, locked
Test time 40S typical
Power supply 180V~270V 50Hz/60Hz auto
Dimention 550*490*580mm
  • Product Show:
Automatic Dielectric Loss Tangent Test Equipment Transformer Tan Delta Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters