• IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
  • IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
  • IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
  • IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
  • IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester

IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester

Product Name: IEC 60754 Cable Corrosion Testing Equipment
Standard: IEC 60754
Application: Wire and Cable Fire Resistance Test
Function: Fire Testing Equipment
System: Computer Control
Power Supply: 110V AC 60Hz / 230V AC 50Hz, 15A
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-IEC60754
Weight
About 60kg
Warranty
12 Months
Transport Package
Plywood Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

 IEC 60754 Cable Corrosion Testing Equipment


Introduction: 

Electric Cables Halogen Acid Gas Release Tester is used to test the acidity of gas that released during combustion from cable or optical cable components materials. This testing equipment is designed and manufactured on the basis of GB/T 17650 and IEC 60754. The cable material is processed by prius tube furnace, and then the PH value and conductivity of the gas that generated in the combustion process and measured, so that the cable material of acidic, as well as concentration of halogen acid gas volume, PH, conductivity, etc, can be determined.

 

Application: 

  • Wire & Cable

 

Reference Standards: 

  1. IEC 60754-1: Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas
  2. IEC 60754-2: Test on gases evolved during combustion of electric cables - Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity.
  3. KS C IEC 60754-1: Tests on gases evolved during combustion of electric cables - Part 1: Measurement of the amount of halogen acid gas.
  4. KS C IEC 60754-2: Tests on gases evolved during combustion of electric cables - Part 2: Corrosiveness test by generating combustion gases.
  5. KWS 409: Wire of Fire Resistance (Fire-Resistance) - 5.12 Causticity for Combustion gas.

 Product Image: 
IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
 

Features: 

1. This testing equipment is designed with optimized structure, logical layout and easy to operate.

2. All the fixture are made of stainless steel.

3. The effective length of the tube-type furnace is 500mm to 600mm, inner diameter is 40mm to 60mm, with the adjustable electric system.

4. Equipped with imported thermocouple from the United States.

5. The size of the combustion boat is length 45mm to 100mm, with 12mm to 30mm, depth 5mm to 10mm.

6. The electrical conductivity measuring range is 0.01uS/mm to 100uS/mm.

7. The control system using electronic temperature control, intelligent control tube furnace temperature.

8. Equipped with two gas collection bottles.

9. Equipped with a PH valued and conductivity detector, with an electronic display and an electrode.

10. Airflow meter is equipped with silicon dioxide fire pipeline to prevent corrosion by the gas.

11. Activated carbon (air filter): filter air through a filter.

12. The silicone is used for the drying air source.

13. Pyrex pipeline: Users can easily insert the sample into the Prius tube to protect the pipeline from damage.

14. Combustion boat moving system: combustion boat moves automatically to achieve more intelligent test.

15. The mode switching: mode switch (two test methods to choose from, IEC 60754-1 & IEC 60754-2).

16. The temperature alarm system: control the furnace temperature against overheating.

17. Timer: IEC 60754-1 & IEC 60754-2 time measuring device.

18. Drawer: used to store part of the box (such as conductivity meter, PH meter, etc.)

19. Temperature indicator: show the furnace core temperature.

20. Permanent magnetic stirrer: the agitator is used to measure the combustion gas conductivity.

 

Specification: 

Sie 1500mm(W)*500mm(D)*600mm(H)
Power 110V AC 60Hz / 230V AC 50Hz, 15A
Weight about 60 kg
Ambient Temperature Operating 10ºC to 35ºC

Packaging & Shipping

Packed in standard export wooden case

 

Company Information

Chongqing Gold, which is dedicated in design, manufacture and service of Fire Testing Equipment.

Since 2009 Gold has developed 70 kinds of instruments and has helped many customers in China, USA, India, Singapore, Pakistan, Indonesia and European.

Major industries including Building materials, Aviation, Rails, IMO, Wire and Cable, Safety Protection, Automotive Interior and so on.
IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
IEC 60754 Cable Corrosion Testing Equipment Fire Resistance Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters