Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year
Still deciding? Get samples of US$ 8000/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
  • Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
  • Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
  • Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
  • Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
Find Similar Products

Basic Info.

Model NO.
GDVA-405
Accuracy Grade
0.02%
Control
Computer Control
Power Source
AC220V
Test Standards
IEC60044-1,2,5,6 , IEC61869-2
Knee Point
Max 45kv
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Power Output
500va
Accuracy
0.02%(Typical); 0.1% (Guaranteed)
Turns Ratio Measurement Range
1~35000
Transport Package
Plywood Case
Specification
39kg
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment For GIS CT Testing

Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
 
1. Introduction

1. GDVA-405 Automatic CT PT Analyzer is a lightweight, robust, portable unit capable of testing accurately tests all types of current and voltage transformers.
2. GDVA-405 Automatic CT PT Analyzer is designed as per IEC60044-1, IEC60044-6, IEC61869-2,IEC60044-2, IEC60044-5, C57.13.
3. It makes evaluation for test results according to selected standards
4. GDVA-405 CT PT Analyzer can make word report for test result
5. GDVA-405 Automatic CT PT Analyzer can make word reports one time for multi-group test records on the PC
6. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
7. Compare excitation curves with saved excitation curves in the same window.


2. Main Test Items for GDVA-405 Automatic CT PT Analyzer
 
Current Transformer Testing Potential Transformer
CT turns ratio test
Ratio and angle error test
Polarity test
Excitation characteristic test
CT secondary winding resistance measurement and secondary burden measurement
CT5% and 10% error curve measurement
Transient characteristics analysis
Automatic nameplate inference
CT knee voltage/current
Accuracy Limit Factor (ALF)
Instrument security factor (FS)
Secondary time constant (Ts)
Remanence coefficient (Kr)
Accuracy
Saturation and desaturation and inductance
Knee point electromotive force
Measurement of parameters such as limit electromotive force and area coefficient
CT core analysis and core hysteresis loop measurement
PT turns ratio test
Ratio and phase angle error test
Polarity test
Excitation characteristic test
PT primary winding resistance
Secondary winding resistance
Secondary load measurement

3. Technical Index
 
1 Test standards IEC60044-1, IEC60044-6, IEC61869-2,IEC60044-2, IEC60044-5, C57.13
2 Power supply AC220V±10%, 50/60Hz±10%
3 Voltage output 0.1~180V (AC)
4 Current output 0.001~5A(RMS)
5 Power output  500VA
6 Max.  knee voltage measurement 45KV
7 Accuracy 0.02%(Typical); 0.1% (Guaranteed)
8 Memory capacity >1000 groups test results
9 Working condition temperature  -10ºC~50ºC; Humidity ≤90%
 
For Current Transformer Testing (CT)
1 Turns ratio measurement 1~40000
1~2000,error<0.05%;
2000~5000, error<0.1%;
5000~40000, error<0.2%
2 Current measurement range 0~10A (automatically change  range in 0.1/0.4/2/10A)
3 Current measurement error <±0.1%+0.01%FS
4 CT Secondary burden range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
5 CT Secondary burden error  <0.2%RDG+0.02%FS
6 CT Secondary burden Max. resolution   0.001ohm
 
For Potential Transformer Testing (CT)
1 Turns ratio measurement 1~30000,
1~2000, error<0.05%;
2000-5000, error<0.1%;
5000~30000, error<0.2%
2 Voltage measurement range 0~200V (automatically change range in 1V/10V/70V/200V)
3 Voltage measurement error < ±0.1%+0.01%FS
4 PT phase angle measurement maximum error  < 5min
5 PT ratio error measurement  1~2000, error 0.1%
6 PT Secondary burden range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
7 PT Secondary burden error <0.2%RDG+0.02%FS

Testing Connection for GDVA-405 Automatic CT PT Analyzer

Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT TestingCurrent Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing
Product Pictures

Current Transformer Automatic CT PT Analyzer Instrument Transformer Testing Equipment for Gis CT Testing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier