ISO 9705 Room Corner Burning Tester for Building Material
ISO 9705 Room Corner Burning Testerfor Building Material (RCT), as ISO's evaluation of the fire-resistance performance of building materials, measures heat release rate (H.R.R), smoke generation rate, oxygen consumption, CO, CO2 production and so on.
As the basis of ISO 9705(Fire tests - Full-scale room test for surface products), RCT is the test that reproduces local fire conditions by flame combustion in the small room of a building structure and measures fire movement and combustion diffusion in the building structure. ISO 9705 states a test method to progress fire generation from the corner of the room and the purpose of this test method is to assess what the surface product supplies to the fire growth using a standard ignition source.
The standard ignition source is stated but another option is also possible. But we must be careful of how the form, position and heat output influence to the fire growth. This method is suitable for the product - materials like thermoplastic resin, insulated circuits, joints, and laboratory having irregular surfaces - which is impossible to experiment with in a small laboratory.
The object of this method does not assess the fire resistance of the product. So Room Corner Tester (RCT) on ISO 9705 assesses the Heat Release Rate about the initial step of fire from ignition to maximum flash-over. The maximum Heat Release Rate can be measured up to 3MW.
Standard
• ISO9705:Fire test-Full scale room test for surface products
• ISO 13784-1: Reaction to fire tests for sandwich panel building systems
• ASTM E 1537: Standard Test Method for Fire Testing of Upholstered Furniture
• ASTM E 603: Standard Guide for Room Fire Experiments
• EN 14390: Fire Test - Full-Scale Room Test for Surface Products
• NFPA 265: Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls
• NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
Specification:
Size |
Test Room (mm): 3,600 (w) × 2,400 (d) × 2,400 (h) |
Power |
220V AC, 60Hz, 10A |
Exhaust |
3.5 m3/s |
Utilities |
Propane Gas Valve System, gnition System |
Feature:
1, Hood Skirt: Hood for collecting flue gases and preventing flue gases of overflow.
2, Strainer for securing stable flow.
3, Suction pump for drawing gases generated in the duct to the Control Lab.
Test Result :
1, Heat Release Rate
2, Smoke Product Rate
3, Consumption and yield measurement of O2, CO, and CO2
4, Analysis of other toxic gases (Others Toxic Gas By FT-IR)
5, Measurement of change in temperature of entrance