Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
  • Audited Supplier
  • 20 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • ASTM D93 Compliance: Designed and manufactured strictly according to ASTM D93 standards for accurate flash point testing.
  • Automatic Operation: Features automatic cover opening, ignition, detection, and result printing for safe and easy use.
  • Data Management: Stores up to 120 groups of test data with automatic correction for atmospheric pressure differences.
  • User-Friendly Interface: Equipped with a light-touch colored LCD and English man-machine dialog interface for easy parameter setting.
  • Lifetime Support: Provides whole life technical support to ensure long-term reliability and customer satisfaction.

Product Images of Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93

Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93 pictures & photos
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93 pictures & photos
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93 pictures & photos
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93 pictures & photos
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93 pictures & photos
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93 pictures & photos
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
  • Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
    Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
  • Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
    Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
  • Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
    Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
  • Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
    Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
  • Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
    Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
  • Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
    Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93

Find Similar Products

Product Description

Gd-261A ASTM D93 Automatic Pensky-Martens Closed-Cup Flash Point Tester

Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93

Product Description


Introduction:
ASTM D93 Automatic Pensky-Martens Closed-Cup Flash Point Tester is designed and manufactured as
per standards  ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.

 

ASTM D93 Automatic Pensky-Martens Closed-Cup Flash Point Tester is used to make determination of
the closed cup flash point of the petroleum products.
 


Features:
1.  Light-touch colored LCD. English man-machine dialog interface. All parameters including preset flash
temperature, sample number, atmospheric pressure and date can be set by prompt menu.
2.  Simulation tracking of temperature rising curve with time. Prompt function. Test date and time can be
modified. 
3.  120 groups of data can be saved.
4.  Automatically calculate the corrected flash point when the pressure differs from standard atmospheric
pressure. 
5.  Differential detection. Automatic correct the system bias. 
6.  Automatically open cover, ignite, detect and print result. 
7.  Safe and easy to operate. 


Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93

 

Product Parameters


Specifications:

Product name GD-261A Automatic Pensky-Martens Closed-Cup Flash Point Tester(ASTM D93)
Power supply AC(220±10%)V,  50Hz
Flash point determination Range: Ambient to 300ºC
Meet requirement of GB/T 261-2008
Meet requirement of GB/T 261-2008
Resulotion: 0.1ºC
Heating rate Procedure A: (5~6)ºC/min
Procedure B:(1~1.5)ºC/min
Automatic control and manually adjustable
Stirring rate Procedure A: (90~120)RPM
Procedure B: (250±10)RPM
Automatic control and manually adjustable
Igniting mode Igniting source: gas (or other civilian fuels)
Electric ignition. Gas flame diameter:3.2mm~4.8mm
Ambient temperature ≤ 40ºC
Relative humidity ≤ 80%
Maximum power consumption 500W
Overall dimension  410*360*310mm

Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93

More Closed Cup Flash Point Apparatus

Model

GD-261

GD-261-1

GD-261A

GD-261D

GD-5208

GD-5208A

Standard

ASTM D93

ASTM D93

ASTM D93

ASTM D93

ASTM D3934

ASTM D3934

Range

ambient~300°C

ambient~250°C

ambient~200°C

ambient~300°C

-30~50°C

50~100°C

Repeatability

≤2°C

≤2°C

Flash point≤104°C,

error: 2°C

Flash point>104°C,

error: 6°C

≤2°C

<2°C(same operator)

<3°C(different operators)

Reproductivity

≤4°C

≤4°C

Flash point≤104°C,

error :4°C

Flash point>104°C,

error:8°C

≤4°C

Automatic up/down

N

N

Y

Y

N

N

With micro printer

N

Y

Y

Y

Y

Y

Display

N

N

Y

Y

Y

Y

Communication port

N

N

N

Y

N

N

 

Sample

 

Standard oil cup

 

Standard oil cup

 

Standard oil cup

 

Standard oil  cup

 

2ml

 

2ml

 

Detail Images:


Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
 

Company  Information:

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

We mainly design and manufacture the petroleum testing instrument  
After several years' development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of petroleum testing instrument .
Fully Automatic Closed Cup Flash Point Analyzer Complied for ASTM D93
Contact Information:
If you have interest, please feel free to contact with me:
Chongqing Gold Mechanical&Electrical Equipment Co., Ltd
website: chinainstrument.en.made-in-china.com

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR229508". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

About Our Factory & Business Background

Address
#2501, China Resources Building, Xiejiawan, Jiulongpo District, Chongqing, 400050, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, CPT
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Chongqing, Shanghai

Our Production Capability & Technical Expertise

Main Products
Oil Purifier, Fire Testing Equipment, Petroleum Products Testing Equipment, Electrical Testing Equipment, Transformer Test Set, Oil Test Kit, Fire Retardant Test, Cone Calorimeter, Bdv Tester, Flash Point Tester

Our Industry Experience & Global Business Record

Export Year
2008-05-03
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What standards does this tester comply with?
The Gd-261A tester is designed and manufactured in compliance with ASTM D93 standards.
What types of samples can be tested?
It is suitable for testing gasoline, jet fuel, diesel, lubricating oil, and other petroleum products.
Does the device support automatic data correction?
Yes, it automatically calculates the corrected flash point when pressure differs from standard atmospheric pressure.
How many groups of data can be saved?
The device can save up to 120 groups of test data.
What is the warranty period?
We provide a 1-year warranty for the product.
What after-sales service is provided?
We offer whole life technical support for all our customers.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now