New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
  • Audited Supplier
  • 20 yrs

Contact Supplier

Product Highlights

  • Dual Standard Compliance: Manufactured to meet ASTM D93 and GB/T 261-2008 standards for accurate flash point testing.
  • LCD Display Interface: Features a full English human-machine interface with menu prompts and guide input function.
  • Automatic Pressure Correction: Automatically calculates and corrects the impact of air pressure on flash point results.
  • Data Storage & Communication: Saves 100 groups of historical data with RS-232/485 ports for long-term computer storage.
  • Electric Ignition System: Uses electric ignition for the gas flame with a single button press operation.
  • Simulation Tracking Display: Visually shows the relationship between temperature rise curves and test duration.
  • 1-Year Warranty Coverage: Provides comprehensive 1-year after-sales service and warranty for all mechanical parts.
  • OEM and ODM Support: Offers customized support including OEM, ODM, and OBM services for various requirements.

Product Images of New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument

New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument pictures & photos
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument pictures & photos
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument pictures & photos
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument pictures & photos
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument pictures & photos
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument pictures & photos
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
    New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
    New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
    New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
    New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
    New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
  • New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
    New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument

Find Similar Products

Product Description

Automatic Pensky-Martens Closed Cup Flash Point Tester
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument

Introduction:

GD-261D Automatic Pensky-Martens Closed Cup Flash Point Tester is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. PMCC Flash Point Tester is used to make determination of the closed cup flash point of the petroleum products.

New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
II. Main technical features:

1. For display, the Closed Cup Flash Point Tester uses an LCD screen. Full English human-machine interface. The target flash point, sample mark number, ambient pressure, test date, etc. can all be set. It has a menu with prompts and a type of guide input function.
2. The Closed Cup Flash Point Tester uses simulation tracking display to show how the function curve of temperature rise and test duration work together. It features immediate operations for English usage, test date, and test time.
3. The standard RS-323,485 computer port is included with the Closed Cup Flash Point Tester. 100 groups of historical data can be saved on the lower computer. If the instrument is connected to a computer, the test data can be communicated, stored for a long time, and updated.
4. Flash Point for Closed Cups The tester can automatically calculate the adjustment and correct the impact of air pressure.
5. Differential detection.
Correct the systematic deviation automatically.
6. Automatically open the lid, detect, and print test results. The test arm automatically raises and lowers.7. The gas flame is lit using an electric ignition in the closed-cup flash point tester. The button will only need to be pressed once.
8. Humanized design. It is safe and really simple to use.


II. Main technical specifications:

 

Heating rate

Procedure A: (5~6)ºC/min, Procedure B: (1~1.6)ºC/min. Automatic control and manually adjustable

 Igniting mode  Electric ignition. Gas flame diameter:3.2mm~4.8mm
 Working condition  Ambient temperature:(10~40)ºC
 Relative humidity  ≤80%
 Maximum power consumption  500W
 Standard  ASTM D93
 

Stirring rate

 Procedure A: (90~120)RPM, Procedure B: (250±10)RPM

Automatic control and manually adjustable

 

Related Products:

GD-261 Pensky-Martens Closed-Cup Flash Point Tester

GD-261-1 Pensky-Martens Closed-Cup Flash Point Tester

GD-261A Automatic Pensky-Martens Closed-Cup Flash Point Tester

New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing InstrumentNew Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument
New Automatic Pensky-Martens Closed Cup Flash Point Testing Instrument

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR229508". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

About Our Factory & Business Background

Address
#2501, China Resources Building, Xiejiawan, Jiulongpo District, Chongqing, 400050, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, CPT
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Chongqing, Shanghai

Our Production Capability & Technical Expertise

Main Products
Oil Purifier, Fire Testing Equipment, Petroleum Products Testing Equipment, Electrical Testing Equipment, Transformer Test Set, Oil Test Kit, Fire Retardant Test, Cone Calorimeter, Bdv Tester, Flash Point Tester

Our Industry Experience & Global Business Record

Export Year
2008-05-03
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What standards does this tester comply with?
The instrument is designed and manufactured according to GB/T 261-2008 and ASTM D93 standards.
How many groups of data can be stored?
The device can save up to 100 groups of historical data on the lower computer.
What is the warranty period for this equipment?
We provide a 1-year after-sales service and warranty for this product.
Does the tester support computer connection?
Yes, it includes RS-232/485 ports to communicate and store test data on a computer.
What is the minimum order quantity?
The minimum order quantity is 1 set.
Can the heating rate be adjusted manually?
Yes, the heating rate is automatically controlled but can also be manually adjusted.
What is the lead time for production?
The lead time is within 15 working days for both peak and off-peak seasons.
Is OEM or ODM service available?
Yes, we offer customized support including OEM, ODM, and OBM services.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now