• PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730
  • PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730
  • PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730

PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Product Name: PV Module Flame Test Equipment
Standard: UL790, UL 1703, IEC 61703-2
Model: Gd-IEC 61730-2
Dimension: 6, 000(W)*2, 200(D)*2, 000(H)mm
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-UL790
Weight
850kg
Exhaust
Minimum 400 M3/Min
Gas
Methane or Liquefied Petroleum Gas
Transport Package
Plywood Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

PV Module Flame Test Equipment, UL  1703, UL  790, IEC 61730

Introduction:
This machine is based on UL790, UL 1703, IEC 61703-2 design and development. Is to simulate real conditions to assess roof and components of fire-resistant performance of the instrument, in A1.82m, b 2.4m and c 3.9m specimens to evaluate A~C level. Also can be used in the fire-retardant performance of photovoltaic components used in this test.
Model: GD-IEC61730-2

Standards:
•  UL 1703: multi-family and hotel room individual dwelling unit smoke detection monitors: electric signal detection of house dust
•  UL 790: the standard method of a fire test for the roof covering materials;
•  ASTM e 108-04: the standard method of a fire test for the roof covering materials;
  NFPA 256: fire test of the roof deck.
•  IEC 61730-2 Appendix b: fire tests on PV modules.

Feature:
1. Plywood roof covering materials, dimensions: 1,300 (w) X1,000 (d) x120 (h), to install the test sample;
2. Non-combustibility test Board, installed at the end of testing, can stop the test panels tempered;
3. Stainless steel fan control board, the test angle can be adjusted, size: 1,440 (l) x 940 (h) mm;
4. Used to support the testing of the mainframe bracket, corrosion-resistant steel, dimensions: 1,020 (l) x 1,000 (d) x 1,473 (h) mm; 
5. Non-combustible plate Assembly, installed in front of the frame to simulate the eaves and cornice, an extension of the flame from the burner to the specimen, dimensions: 300(W) x 2130(D) x 584 (H) mm;
6.Airflow rate for the test panel: 19 ± 8 km/h (5.5M/sec), and configure the anemometer monitor;
7. Separate ventilation pipes, can be extracted from outside the laboratory air;
8. Honeycomb filter is installed in the air duct, installed gas inlet guide vane;
9. Ventilation ducts equipped with slope adjustment panel for adjusting the air flow direction;
10. Ventilation pipes attached to the Guide, can enhance speed to ensure supply test airflow from the outside interference, guide plates made of stainless steel, location does not change with the wind pressure;
11. Duct materials for stainless steel, corrosion-resistant and heat-resistant, size: 2,130 (w) x 762 (h) x 3,000 (l) mm;  
12. Fan 220V,50HZ, three-phase power, is equipped with a reverse system can automatically adjust the wind speed, minimum flow for 300m3/min;  
13. Infinitely variable speed inverter, 0-100% adjustable;
14. Gas burners (for intermittent Shi Huo, flame spread and flying fire), 1.12m, 60.3mm, moving in the test side has a 12.7mm (w) *0.91m (long) slit;    
15. The gas burner can provide a 22,000Btu/min (387kWh), and according to a, b, c three combustion levels, high-precision gas control valve controlling gas flow,
16. Top burner thermocouple is installed 58.7mm, 888 ± can test 28 ºC;
17. Automatic ignition system, ensure the security of test performance, ignition electrode 1.8kVp mass flow controller is the minimum pressure according to different standards, control gas flow rates, Class A and B:21,000 ~ 22,000 Btu/min (369 ~ 387 kWh) for 10 minutes, Class C:18,000 ~ 19,000 Btu/min (316 ~ 334 kWh) 4 minutes;
18.Temperature control system-Class A and B:760±28ºC (1400±50ºF)-21,000 ~ 22,000 Btu/min-Class C:704±28 c (1300±50ºF)-18,000 ~ 19,000 Btu/min
19. High precision pressure gauges and pressure regulating valve controls the gas pressure;
      1)-Each transfer to gas in the burners need to follow a different test and control methods;
      2)-LNG: using MFM can accurately measure flow (flow control valve control);
      3)-LPG: air flow rate using the inverter system: the test deck at 19 ± 8 km/h (5.5M/sec);
 20. Metallic mesh support materials, pallets can be rotated, so that full combustion of materials;

Test results:
1, Computer control system of United States special control software for Labview experiment,
2, Data acquisition systems, LabView programming language is used to program.
3, Data acquisition system consists of the following parts:
     1) 16-bit thermocouple input module
     2) 16 bit a/d conversion input module
     3) Data input/output module
     4) 12 bit a/d conversion output module
     5) 4 and 8-slot backplane
     6) Labview modules
     7) Labview/Ethernet network module
4, Brand testing systems, gas burners, the flame engulfed the burning material, the gas burner is 880±10ºC temperature can be adjusted;

The standard results
1, General standards for flame spread
• Any part of the roof covering materials (component or Panel) from the test deck in flame or glowing particles blown,
• Can slide through, split, curved roof covering materials, such as roof deck open,
• Fire safety rating A: flame spread range is 1.82M,
  Fire safety level B: flame spread range is 2.4M,
  Rank C fire safety: fire spreading area is 3.9M,
   Measured from the edge of the sample spread of flame,
2, General standards for roof combustion,
•  Any part or component of the Panel from the test deck in flames blowing or falling,
•  Parts of the roof deck or a part of a Panel in the roof structure or component in the form of luminous particles disappear,
•  Continue with components or panels of combustion,

Specification:
 Model GD-IEC 61730-2
Dimension About 6,000 (w) X2,200 (d) X2,000 (h) mm
Weight 850kg
Exhaust Minimum 400 m3/min
Gas Methane or Liquefied petroleum gas

Product details:
PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730

Our company:   

Since 2008, Gold has developed 70 kinds of fire testing instruments and served for many industries such as building materials, aviation, rails, IMO, wire & cable, safety protection and so on.

Our mission is to provide reliable products to our customers to meet their requirements of testing, R&D and quality control. In addition, Gold insists for high-quality standard in niche markets and targets to minimize the gap between Chinese local products and imported products.

We work with trust, honesty and a sense of responsibility, so the quality and service are always our advantages among all competitors.

PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730
PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730
PV Module Flame Test Equipment, UL 1703, UL 790, IEC 61730

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters