Customization: | Available |
---|---|
After-sales Service: | All Life Technical Supports |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
EN 13823 Single Burning Item SBI For Building Materials
Introduction
EN 13823 Single Burning Item SBI For Building Materials (SBI), as European's evaluation of the fire-resistance performance of building materials, measures heat release rate (H.R.R), smoke growth rate index (SPR), oxygen consumption, CO, CO2 production, mass loss rate and so on.
EN 13823 Single Burning Item SBI For Building Materials test method is to measure the response behavior of the product for building materials (except flooring materials) against fire when the product for building materials is exposed to heat attack(by Sand-Box burner of propane fuel) from Single Burning Items.
The specimen is settled on the Trolley (moving cart) located in the Frame just below the emission system. The response of the specimen against the burner is displayed mechanically and visually. Mechanically, it calculates Heat Release Rate (H.R.R) and Smoke Release Rate (S.R.R), and physical properties are evaluated by visual observation. Measuring the range of SBI, the Fire Growth Rate Index (FIGRA) by oxygen consumption quantity of combustion products is the most representative measuring element; otherwise, representative measuring elements are oxygen consumption, CO, CO2 production, Smoke Growth Rate Index (SMOGRA) and so on. The maximum heat release rate can be measured up to 1MW.
Standard
• BS EN 13823: Reaction to fire tests for building products excluding floorings exposed to the thermal attack by a single burning item
Specification
Size:
Test Room (mm): 3,000 (w) * 3,000 (d) * 2,600 (h)
Hood (mm): 1,450 (w) * 1,255 (d) * 1,093 (h)
Sandbox Burner (mm): 250 (w) * 250 (d) * 80 (h)
Power Voltage: 220 V,60 Hz,20 A
Exhaust : 0.55 m3/s ~ 0.65 m3/s
Control Unit
• Main Sandbox Burner & Trolley
• Fixed Frame & Auxiliary Burner
• Hood
• Collector
• Measuring Tube(J-Shaped)
• Sandbox Burner ( Main & Auxiliary )
• Gas Diverter
• Smoke Exhaust System
• Three Thermocouples(by EN 60584-1)
• Bi-directional Probe
• Gas Sampling Probe
• Analyzer ( O2 ,CO2, CO )
• Light Attenuation System
• Atmospheric Pressure Measurement
• Cold Trap
Auxiliary
• Propane Gas & 2 Stage Regulator
• N2 & CO/CO2 Gas & 2 Stage Regulator
Specification:
Production name | En 13823 Single Burning Item Sbi for Building Materials |
Cart size | 1500mm (W) X 1620mm (D) X 2200mm (H) |
Frame size | 1700mm (W) X 2500mm (D) X 2200mm (H) |