Test method of HIPOT withstand voltage test
A voltage withstand tester usually connects one side of the power supply to a safety ground (earth). The other end of the power supply is connected to the conductor under test. By connecting the power supply in this way, you can connect the given conductor to two positions: high voltage or ground.
If you have more than two contacts to be tested for voltage resistance, you can connect one contact to high voltage and ground all other contacts. Testing the contact in this manner ensures that it is isolated from all other contacts. If the insulation between the two is adequate, then applying a large voltage difference between the two conductors separated by the insulator will result in a very small current flow. Although this small current is acceptable, no breakdown of either the air insulation or the solid insulation should occur. Therefore, the perceived current is the current due to partial discharge or breakdown, not the current due to capacitive coupling.
The typical application of the HIPOT tester is as follow:
Power Transformer AC high voltage withstand test
Circuit Breaker AC high voltage withstand test
High voltage motors high voltage withstand test
Voltage/current transformer high voltage withstand test
High voltage power source for calibration of high voltage meter
Model Selection Table:
Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.
The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order.
Capacity | GDJZ-50 Series | GDJZ-100 Series | GDJZ-150 Series | |||
KVA | AC | DC | AC | DC | AC | DC |
3kVA | 50KV | 70KV | ||||
5kVA | 50KV | 70KV | 100KV | 140KV | ||
10kVA | 50KV | 70KV | 100KV | 140KV | 150kV | 210KV |
15kVA | 50KV | 70KV | 100KV | 140KV | 150kV | 210KV |
20kVA | 50KV | 70KV | 100KV | 140KV | 150kV | 210KV |
25kVA | 50KV | 70KV | 100KV | 140KV | 150kV | 210KV |
30kVA | 50KV | 70KV | 100KV | 140KV | 150kV | 210KV |
50kVA | 50KV | 70KV | 100KV | 140KV | 150kV | 210KV |