Automatic Limited Oxygen Index (LOI) Tester
Introduction
1. The limiting oxygen index refers to the volume fraction concentration of oxygen in a mixed gas of oxygen and nitrogen when the polymer can just support its combustion, and it is an index that characterizes the combustion behavior of materials. The oxygen index value of a polymer is the minimum volume percentage of oxygen in a mixed gas of oxygen and nitrogen required to keep burning 50 mm or burning time 3 minutes after the substance is ignited. The limiting oxygen index refers to the minimum oxygen concentration required for a material to burn flamingly in an oxygen-nitrogen mixed flow under specified conditions, expressed in terms of the volume percentage of oxygen.
2. The instrument is simple in structure and easy to operate. It can be used as a means to identify the combustion performance of compounds, and can also be used as a related research tool, so as to obtain a better understanding of the combustion process of polymers. This instrument is suitable for testing the combustion performance of plastic, rubber, foam and other materials.
3. The instrument adopts mass flow meter + touch screen control, the oxygen concentration does not need to be manually adjusted, but the value can be set in the touch screen, this function greatly reduces the test process time and improves the control accuracy of the oxygen concentration.
Standard:
- GB/T 2406 - 2009
- ISO4589.2 - 1996
Technical Parameters:
- Inner Diameter of Combustion Tube: 90mm
- Height of the Combustion Tube: 450mm
- Pipe Hole Diameter of the Long Pole Igniter Trailing End: φ2 ± 1mm
- Nitrogen Mass Flowmeter: 20L/min
- Oxygen Mass Flowmeter: 20L/min
- Touch Screen: 7 inches
- Precision of Pressure Gauge: level 2.5
- Resolution of Pressure Gauge: 0.01Mpa
- Resolution of Oxygen Concentratation Indicator: 0.1%
- Oxygen Sensor: imported from Germany with high precision
- Gas Source: the GB3863 specified oxygen, the GB3864 specified nitrogen
- Experiment Environment: Temperature: 10 ~ 35ºC Humidity: 45 - 75%
- Input Pressure: 0.2 - 0.3Mpa
- Working Pressure: 0.05 - 0.15Mpa
- Sample Type: self-supporting materials and non-self-supporting materials
- Oxygen Index die: 10mm * 100mm
Specifications:
- Dimensions: 850mm(L) * 450mm(W) * 985mm(H)
- Power Supply: AC220V, 50/60Hz, 5A
- Air Source: oxygen, nitrogen (provided by the customer)
- Portable Gas Stove (provided by the customer)
Automatic Limited Oxygen Index (LOI) Tester
Limiting Oxygen Index Testing Equipment
ISO4589 LOI Limited Oxygen Index Tester
Oxygen Index Apparatus