Wire and Cable Fire Resistance Tester IEC 60331
Introduction:
Fire-resistant cable refers to a cable that can keep a safe running time in the case of flame combustion.
IEC 60331 divides the fire resistance test into A, and B two classes, The flame temperature of A grade is 950 ~ 1000 ºC, and the continue flaming time is 90min, B grade flame temperature is 750 ~ 800 ºC, the flaming time is 90 min. In addition, the test specimen shall bear the rated voltage during the test. The fire Resistance Tester is designed according to the requirements of IEC60331-11 and used to obtain the refractory characteristics of a fire-resistant cable or optical cable under flame conditions.
Standards:
IEC 60331 Part 11
IEC 60331 Part 21
BS 6387(Option)
Main Features:
1. All fixtures are made of stainless steel;
2. The burner is a belt-type propane blowtorch with a Venturi mixer, and the burner nozzle is length 500mm, width 15mm;
3. Those burning holes are staggered into 3 rows, and the front width is 15mm, the holes diameter is 1.32mm and these holes center distance is 3.2mm;
4. One end of the specimen holder is equipped with a clamp to fix the sample, and the other end is convenient for heat transfer along the longitudinal specimen;
5. The cable sample is supported by two metal rings, and the middle length of the two rings is about 300mm;
6. An inner diameter of the sample supporting metal rings is 150mm, and the cross-sectional diameter of the ring is 10 ± 2mm.
7. The position of the burner torch from burning the bottom is not less than 200mm, and not less than 300mm from the tank wall.
Combustion System:
1. Independent standard electrical control platform;
2. With an intelligent detection function, when a short circuit in the sample during the test, an automatic alarm turns off the fire source.
3. Fuse current in the experimental circuit is 2A;
4. The sample is applied to the power of AV 100V ~ 1000V adjustable; 5, The time can be set free for the fire, the time recommended by standards is 90min.
Device parameters:
1. Voltage: AC 380V 3-phase, 50 / 60Hz, 30A;
2. The input voltage 0 ~ 1000V; can be adjusted;
3. The breakdown current is 2A;
4. Maximum power: 5000VA;
5. Timer: 0 ~ 999min
6. The flame temperature of 0 ~ 1100 ºC adjustable;
7. The test load current is 0.25A, and can be adjusted;
Specification:
Size |
1,600 (W) × 850 (D) × 1,650 (H) mm |
Console size |
600 (W) × 750 (D) × 1,200 (H) mm |
Power |
AC 380V 3-phase, 50 / 60Hz, 30A |
Weight |
100kg |
Product Images: