• Current and Potential Transformer Analyzer CT PT Tester
  • Current and Potential Transformer Analyzer CT PT Tester
  • Current and Potential Transformer Analyzer CT PT Tester
  • Current and Potential Transformer Analyzer CT PT Tester
  • Current and Potential Transformer Analyzer CT PT Tester
  • Current and Potential Transformer Analyzer CT PT Tester

Current and Potential Transformer Analyzer CT PT Tester

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer CT PT Tester
Type: Transformer CT PT Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 6000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDVA-405
Display
Digital
Control
Manual Control
Weight
15kg
Power Source
AC220V
Apparatus
IEC60044 Electronic Current Transformers Tester
Application
IEC 60044 Transformer CT PT Analyzer
Function
Electronic Voltage Transformers Tester Analyzer
Device
CT PT Transformers Comprehensive Analyzer
Test Standards
IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Power Output
500va
Maximum Knee Voltage Measurement
45kv
Memory Capacity
>1000 Groups Test Results
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
100PCS/Month

Product Description

Current and Potential Transformer Analyzer CT PT Tester

Current and Potential Transformer Analyzer CT PT Tester
1. Equipment Description
 
Tests for Current Transformer: Tests for Potencial Transformer:

1.Excitation curve and parameters test
2.Turns ratio test
3.Ratio and phase error test
4.Polarity mark check
5.Winding resistance measurement
6.Secondary loop burden measurement
7.Error line curve test for protection CT
8.Transient CT parameters test
9.CT nameplate guess
10.Saturation hysteresis loop curve measurement
1.Turns ratio test
2.Ratio error and phase angle error test
3.Polarity test
4.Secondary burden test
5.Winding resistance test

Applications of CT PT Analyzer:
 
1.CT nameplate check
2.CT parameters check in work burden
3.CT transient parameters analysis
4.CT ratio and phase error calibration
5.PT routine test

2.Technical Parameters:
 
1.Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2.Power supply: AC220V±10%, 50/60Hz±10%
3.Voltage output: 0.1~180V (AC)
4.Current output: 0.001~5A(RMS)
5.Power output: 500VA
6.Maximum knee voltage measurement: 45KV
7.Current measurement:
   Range: 0~10A (automatically change range in 0.1/0.4/2/10A) 
   Error: <±0.1%+0.01%FS
8.Voltage measurement:
   Range: 0~200V (automatically change range in 1V/10V/70V/200V)
   Error: < ±0.1%+0.01%FS
9.Turns ratio measurement:
   Range:1~35000
   1~2000     error<0.05%
   2000~5000  error<0.1%
   5000~35000  error<0.2%
10.Phase measurement: error: ±2min;    resolution: 0.01min
11.Winding resistance measurement: 
    Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
    Error: < 0.2%RDG+0.02%FS
    Maximum resolution: 0.1mΩ
12.Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree

13.CT Secondary burden:
    Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
    Error: <0.2%RDG+0.02%FS 
    Maximum resolution: 0.001ohm
14.PT Secondary burden:
    Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
    Error :<0.2%RDG+0.02%FS 
    Maximum resolution: 0.1ohm
15.PT ratio measurement:
    Range: 1~35000
    1~10000 error<0.1%
    10000~35000 error<0.2%
16.PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%
17.PT phase angle measurement: maximum error < 3min
18.Make evaluation for test results according to selected standards
19.Make word report for test result
20.Make word reports one time for multi-group test records on the PC
21.Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
22.Compare excitation curves with saved excitation curves in the same window
23.Memory capacity: >1000 groups test results
24.Working condition: temperature: -10ºC~50ºC; moist: ≤90%
Current and Potential Transformer Analyzer CT PT TesterCurrent and Potential Transformer Analyzer CT PT Tester
Customer Visit
Current and Potential Transformer Analyzer CT PT Tester
Exhibition
Current and Potential Transformer Analyzer CT PT Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now