Introduction
Wire and Cable is the second-largest industry. Single wire and cable vertical burning tester are the most widely used and low-cost cable fire performance test equipment; Single wire or cable burning tester meets the national standard GB /T18380.11-2008 / IEC60332-1-1: 2004 requirement. It is to test the flame retardant insulation layer under fire conditions applicable for testing wire and cable in overheating, over-current, and other non-normal state. It can be used for vertical or fiber optic wire and cable flame spread tests, and test combustion conditions of Dettol matter under fire conditions.
Standard
IEC 60332-1-1,2,3
EN 50086-1-1994
GBT 18380.11,12-2008
Main features
Touch screen intelligent control system; English user interface;
Automatic ignition system, automatic timing, automatic data storage;
The test section and the control section are combined designs in one box for operation;
Stainless steel test box, the internal cavity size: height 1200mm, width 300mm, depth of 450mm;
A pre-mixed burner, with an inner diameter of ¢ 12 ± 0.5mm, and a length is 100mm. 1KW hybrid standard burner, which provides an accurate test fire source;
The flame burning applied time and hold time can range from 0 to 99 minutes99 seconds range adjustment. Automatic control of the testing process.
The imported needle valve precisely adjusts the flame height, according to standards, the blue flame height is 50mm ~ 60mm, total height is 170mm ~ 190mm
The gas flow rate is controlled by a needle valve
Equipped with a flame height caliper.
Equipped with a gas flow meter and pressure regulator; automatic ignition.
The torch angle is 45 °, 0 ° adjustable.
The flame calibration device is optional.
Specifications | |
Operating voltage |
AC220 V ± 10V 50HZ |
Ambient temperature |
room temperature ~ 40 ºC |
Gas Pressure |
0.1MPa |
Gas purity |
Propane> 95%; compressed air |
Timing Accuracy |
0.1s |
Model |
GD-IEC60332-1 |
Size |
600(W)×450(D)×1250(H)mm |
Power |
AC 220V, 50/60Hz, 3A |
Weight |
60kg |
Manual |
Provide |