• 6 Phase Secondary Injection Tester Relay Protection Test Set
  • 6 Phase Secondary Injection Tester Relay Protection Test Set
  • 6 Phase Secondary Injection Tester Relay Protection Test Set
  • 6 Phase Secondary Injection Tester Relay Protection Test Set
  • 6 Phase Secondary Injection Tester Relay Protection Test Set
  • 6 Phase Secondary Injection Tester Relay Protection Test Set

6 Phase Secondary Injection Tester Relay Protection Test Set

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for 6 Phase Relay Tester
Type: 6 Phase Relay Tester
Load Way: Electronic Load
Loading Method: Static Load
Display: Digital
Samples:
US$ 4000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDJB-PC6
Control
Manual Control
Power Source
AC220V
Product Name
6 Phase Secondary Injection Tester
Application
Six Phase Relay Test Set
Function
Six Phase Relay Protection Test Set
AC Current Source
6 Phase Parallel Current Output
DC Current Source
20A / Phase, Power: 300va/Phase
AC Voltage Source
Phase Voltage Output:6X( 0~125V)/Phase
DC Voltage Source
0~150V Accuracy: 0.5%
Ime Measurement Range: Range
1ms-9999s; Accuracy: 1ms
Transport Package
Standard Venner Case
Specification
ask the salesman
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month Relay Test Set

Product Description

6 Phase Secondary Injection Tester Relay Protection Test Set

6 Phase Secondary Injection Tester Relay Protection Test Set

Introduction

The six-phase relay protection device tester is a device specially used to test and calibrate relay protection devices in six-phase power systems. It has multiple functions and features, and can fully cover the testing and calibration of relay protection devices with six phases or more. It is widely used in the field of relay protection device testing and evaluation of power systems, including power system operation and maintenance, fault analysis, new device commissioning, equipment research and development and production, etc.

Features

  • Meets all the requirement of field tests. This tester with standard 6 phase voltage6 phase current output,voltage 125V/phasecurrent 30A/phase, 6 phases in parallel can up to 180A. Digital Signal Processor Microcomputer. Not only test the traditional relays and protectors, but also test the modern micro computer replays, special for transformer differential protection and transfer equipments.
  • All technical indicators fully meet the standard DL/T624-1997: Technical condition of the relay computer test device.
  • Classic Windows XP operating interface, friendly man-machine interface, easy and fast to operate; High-performance embedded industrial control computer and 8.4 inch 8.4 - inch resolution of 800 × 600 TFT true color display which provides rich visual information, includes the current working condition and all kinds of help information.
  • The Windows XP system comes with the restore function; avoid system crashes caused due to illegal shutdown, or malfunction, etc.
  • Equipped with ultra-thin industrial keyboard and optical mouse, complete a variety of operations using keyboard or mouse the same as ordinary PC.
  • The main control board is DSP + FPGA architecture, 16 bit DAC output, generates high - density sine wave 2000 points each circle to fundamental wave, which greatly improve the wave quality and the accuracy of the test instrument.
  • Using high-fidelity linear amplifier. Both to ensure the accuracy of a low current, but also guarantee the stability of the high current.
  • USB directly connect with PC, without any adapter cable, easy to use.
  • Can be connected to a laptop computer (optional).Laptop computers and industrial machines use the same software, no need to re-learn the methods of operation.
  • With GPS synchronization test function. The device can be built-in GPS synchronization card (optional) connects with PC by RS232; people can do remote synchronization swap test for the two testers.
  • With a separate DC auxiliary voltage source, output voltage 110V(1A),220V(0.6A), provides relays or protective devices which require DC power.
  • The software with self calibrating function, which avoid to calibrate accuracy by adjusting relays after open the case, greatly improve the stability of the accuracy. 

Technique Parameters

 Main Parameters

Current Channels

Standard 6 Phase

Voltage Channels

Standard 6 Phase

AC Current output range

30A/Phase or 180A (6 Phase)

DC Current output range

DC 10A/ Phase

AC Voltage output range

AC 120V/ Phase

DC Voltage output range

DC 160V/ Phase

AC current source

Output Accuracy

0.2%

6 phase current output per phase output (effective value)

0~30A

3 phase current output per phase output (effective value) 0~30A

6 phase in parallel max output

180A

Phase current values allowed to work a long time

10A

 

Phase current Max output power

300VA/phase

6 phase in parallel max output power

1000VA

6 phase in parallel current max output allowable working time

10s

Frequency range

20~1000Hz;

accuracy: 0.001Hz

 

Harmonic times

2~20; phase :0~360°;

accuracy: 0.1°

DC current source 

Output Current

0~±10A /phase

Maximum output load voltage

20V

Accuracy

0.2%


AC voltage source 

Output Accuracy

0.2%

Phase voltage output (effective value)

0~120V

Phase voltage / Line voltage output power

80VA/100VA

Line voltage output (effective value)

0~240V

Frequency range

20~1000Hz

Harmonic Times

1~20

 

DC voltage source

Phase voltage output range

0~±160V 

Accuracy

0.2%

Line voltage output range

0~±320V

Phase voltage / Line voltage output power

70VA/140VA

 

Switch terminal

Switch input terminals

10 pairs

 

The empty contacts

1-20mA, 24V 

Potential flip

"0"0~+6V DC low level;

"1": +11~+250V DC high level

Switch output terminals

8 Pairs,

DC220V/0.2A;

AC220V/0.5A.

 

Time measurement range

Range

0.1ms~9999s

Accuracy

<0.1ms

 

Dimension & weight

Dimension

455×530×220mm

Weight

32Kg

 

Power Supply

AC220V±10%; 50Hz/60Hz.

Working Temperature

-10~+50ºC


Item Show

6 Phase Secondary Injection Tester Relay Protection Test Set
6 Phase Secondary Injection Tester Relay Protection Test Set

6 Phase Secondary Injection Tester Relay Protection Test Set

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now