• Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
  • Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
  • Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
  • Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
  • Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
  • Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil

Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil

After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Transformer Oil Dissipation Factor Test
Power Source: AC 220V±10% Without Frequency Limit
AC High Voltage Output: 400V-2200V ±2% Every 100V 50va
DC High Voltage Output: 00V-2200V ±2%
Temperature Control Induction Stove: Max Power 500W
Customization:

Contact Supplier

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
GDGY
Temperature Control Range
<100ºC
Control Temperature Error
0.1ºC
Control Temperature Time
Room Temperature 90ºC <20min
Measuring Range
Tgδ Without Limit;Cx 15PF-300PF;Rx 10m-10t
Product Name
Oil Tan Delta Tester
Transport Package
Standard Wooden Case
Specification
30kg
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
200piece/Month

Product Description

Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil


Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
Product Description

 

  • GDGY Automatic Transformer Oil Tan Delta Tester is integrated by oil cup for dielectric loss, temperature-control equipment, temperature sensor, test-bridge for dielectric loss, AC trial electrical source, standard capacitor, high resistance meter and DC high-voltage power etc. 

  • The most advanced heating mode of high frequency induction is applied to the heating part of this instrument, which has the advantage of non-contact of oil cup and heating unit, homogeneous heating, quick velocity and convenient control etc.

  • AC-DC-AC conversion mode is applied to AC trial electrical source so that the problem how to measure correctly under the fluctuation of voltage and frequency can be avoided. Even when the electric generator is working, the instrument can operate correctly. 

  • The inner standard capacitor is SF6 three-pole inflate capacitor, whose dielectric loss and capacitance is not influenced by environmental temperature and dampness etc. In this way, the accuracy of the instrument is guaranteed conformably after a long-time application.


Specifications:

Item Name

GDGY Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil

Condition of Use

-5ºC-40ºC RH<80%

Power Source

AC 220V±10% Without Frequency Limit

AC High Voltage Output

400V-2200V ±2% Every 100V 50VA

DC High Voltage Output

00V-2200V ±2%

Temperature Control Induction Stove

Max Power 500W

Temperature Control Range

<100ºC

Temperature Measuring Error

±0.5ºC

Control Temperature Error

0.1ºC

Control Temperature Time

Room Temperature 90ºC <20min

Measuring Range

tgδ Without Limit

Cx 15PF-300PF

Rx 10M-10T

Resolution

tgδ 0.001%

Cx 0.01pF

Rx 0.01

Precision

delta tgδ:±(Reading*0.5%+0.020%)

delta Cx :±(Reading*0.5%+0.5PF)

delta Rx :±Reading * 10%

Relative Dielectric Loss Constant

Εr Calculated Automatically

Volume Resistivity

ρ Calculated Automatically

Dimension

450(L)×310(W)×360(H)

Net Weight

30KG


Real Pictures:
Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil
Easy to Clean Dissipation Factor and Tan Delta Tester for Transformer Oil



 

Send your message to this supplier

*From:
*To:
avatar Mrs. Ivy Zhang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now