• ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
  • ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
  • ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
  • ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
  • ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
  • ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil

ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil

After-sales Service: Lifetime Technical Support
Warranty: 2 Year
Max Diameter of Workpiece: 500mm
Mass Scope of Workpiece: <900kg
Type: Universal Testing Machine
Maxcapacity: <1000KN
Samples:
US$ 3200/Set 1 Set(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Main technical features
  • Product Parameters
  • Comparison
  • Take photos on site
  • Contact us
Overview

Basic Info.

Model NO.
GD-3536D
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Top
Temperature Range
Ambient Temperature-400ºC
Ignition Mode
Automatic
Temperature Display
Color LCD
Printing
Yes
Communication Port
Yes
Dimension
520*380*310mm
Reference Standard
ISO 2592, ASTM D92
Other Function
Automatic, with RS232 Communication Port
Igniting Mode
Electric Ignition
Power Supply
220 V
Transport Package
Wooden Case for Gd-3536D
Specification
520*380*310mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
100 Sets/ Month

Product Description

GD-3536D Automatic Cleveland Open Cup COC Flash Point Tester for Oil

Product Description

Fully-Automatic Cleveland Open Cup Flash Point Tester can be widely used in railway,aviation,electric power, petroleum industry and colleges,scientific research institutes,measurement departments to do determination of flash point and fire point for petroleum products. It adopts desktop structure and advanced design.The man-machine interface make it easy to use.And the test result is accurate.

Automatic Cleveland Open Cup Flash Point Tester is designed and made as per ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is a kind of fully-automatic instrument which can do determination for both flash point and fire point.

Main technical features

Automatic Cleveland Open Cup Flash Point Tester  adopts technology of single chip microcomputer and LCD screen.Full English man-machine dialog interface. It can preset the parameters of expected flash point,sample mark number, atmospheric pressure, test date,etc.It has menu to prompt and input function of guide type.
ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil

 

Product Parameters

Product name GD 3536D Fully-Automatic Cleveland Open Cup COC Flash Point Tester 
Power supply AC(220±10%)V, 50Hz
Flash point determination Range:Ambient to 400ºC
Repeatability:  ≤8ºC
Reproducibility: ≤17ºC
Accuracy: 0.1ºC
Heating rate Correspond with GB/T3536 and ASTM D92
Igniting mode Electric ignition, 
Gas flame diameter: 3.2mm~4.8mm
Ambient temperature (10 ~ 40)ºC
Relative humidity ≤80%
Maximum power consumption 500W
Dimension 520*380*310mm

 

GD-3536 Series ASTM D92 CLEVELAND OPEN CUP FLASH POINT TESTER:

Parameter

GD-3536

GD-3536-1

GD-3536A

GD-3536D

Temperature range

Ambient temperature~400ºC

Ambient temperature~400ºC

Ambient temperature~400ºC

Ambient temperature~400ºC

Ignition mode

 once manually

once manually

 once manually

Automatic

Temperature display

Thermometer

LCD

Color LCD

Color LCD

Printing

No

No

Yes

Yes

Communication port

No

No

No

Yes

Other function

Manually adjust heating rate

Automatically control temperature and display by LCD

Automatic

Automatic, with RS232 communication port

Dimension

350*290*350mm

340*320*450mm

410*360*420mm

520*380*310mm

Comparison

What is the difference between Open Cup Flash Point Tester and Closed Cup Flash Point Tester?
The implementation standard of the open cup flash point tester is GB/T3536-2008, which is used to measure petroleum products other than fuel oil with an open cup flash point higher than 79 degrees.
The closed flash point implementation standard GB/T261-2008 is used to measure flammable liquids, liquids with suspended particles, and liquids whose surfaces tend to form a film under experimental conditions.
Generally speaking, the closed-mouth measurement measures light oil or oil used under sealed conditions, such as transformer oil. Opening measures heavy oils or oils used under open conditions, such as lubricants.
When purchasing, it is still recommended to choose a fully automatic instrument. Manual instruments save money and have high requirements on operators. Moreover, each person's different habits and on-site test conditions will affect the test results.

 

Take photos on site

ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil
ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil

Contact us

If you have interested in ASTM D92 Automatic Cleveland Open Cup Flash Point Apparatus for Oil, please feel free to contact with me:
Chongqing Gold Mechanical&Electrical Equipment Co., Ltd
   
website: chinainstrument.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters