• Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
  • Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
  • Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
  • Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
  • Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
  • Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis

Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis

After-sales Service: Lifetime Technical Support
Warranty: 1 Year Fortransformer Oil Analysis Gas Chromatogra
Test Item: Ransformer Oil Analysis Gas Chromatograph Detecto
Standard: IEC 60599/IEEE C57/ASTM D3612
Power Supply: 220V±10%, 50Hz
Power: ≤500W
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-3100E
Program Rise Rate
0.1~60°c/Min
Program Boost
8 Steps
Transport Package
Standard Venner Case
Specification
625*500*297mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
1000PCS/Month

Product Description

 
Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis

Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis


Product description

GD-3100E Portable Transformer Oil Chromatograph adopts the classic three-detector process, a sample can be completed in the insulating oil dissolved in the content of H2, CO, CO2, CH4, C2H4, C2H6, C2H2 and so on 7 kinds of gas components of the whole analysis. The instrument integrates computer, gas source and other components together, and the whole system is compressed into 2 pieces of portable chromatography and portable oscillator, which makes it portable in the true sense.

Compliance with standards

Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
1,GB/T 17623-2017 Determination of dissolved gas components in insulating oil by gas chromatography
2,GB/T 7252-2001 Guidelines for analysis and judgment of dissolved gases in transformer oils
3,DL/T 722-2014 Guidelines for analysis and judgment of dissolved gases in transformer oils

Technical characteristics
  1. Triple detector process technology for complete separation of all components
  2. FID detector flameout protection
  3. Gas break protection function
  4. Fast converter cooling down technology, realize fast shutdown
  5. Injector self-starting device to ensure the repeatability of retention time
  6. FID detector with logarithmic amplification circuit, wider range and lower detection limit.
  7. The instrument comes with aging program, users can directly select the automatic aging instrument, without the need for complex settings
  8. Highly integrated and modularized structure design
  9. New IC control system design
 
Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis
Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis




Limit of detection (µL/L):
 
Components Detection limit Components Detection limit
H2 2 C2H4 0.05
CO 2 C2H6 0.05
CO2 5 C2H2 0.05
CH4 0.05    

Detector technical specifications:
 
Thermal Conductivity Detector (TCD) Hydrogen flame ionization detector (FID)
Semi-diffusive structure Programmed auto-ignition (above 130°C auto-ignition)
Power supply with constant current control Automatic ignition; stabilization time: 10 minutes
Sensitivity: ≥10000mV-ml/ mg (benzene) Detection limit: ≤3x10-12g /s (n-hexadecane/isooctane)
Baseline noise: ≤10uV Baseline noise: ≤5x10-14A
Baseline drift: ≤30uV/30min Baseline drift: ≥1x10-13A/30min
Linearity: ≥105 Linearity: >107

Temperature control indicators:
 
Temperature control part Temperature control range Temperature Control Precision
Column box 4°C~450°C above room temperature ±0.01°C
Hydrogen Flame (FID) Detector 4°C~450°C above room temperature ±0.01°C
Thermal Conductivity (TCD) Detector 4°C~450°C above room temperature ±0.01°C
Ni Catalyst Converter 4°C~450°C above room temperature ±0.01°C
Steps of programmed temperature increase 20 steps  
Program Rise Rate 0.1~60°C/min ±0.01°C
Program Boost 8 steps  

Other Parameters:
Dimensions: 625*500*297mm
Weight: 20kg
Power supply: 220V±10%, 50Hz  
Power: ≤500W

Portable Transformer Oil Analysis Gas Chromatograph Detector Transformer Dga Dissolved Gas Analysis

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters