Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Turns Ratio TTR Instrument
Still deciding? Get samples of US$ 2200/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
  • Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
  • Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
  • Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
  • Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
  • Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
Find Similar Products

Basic Info.

Model NO.
GDBC-901
Type
Transformer Turns Ratio TTR Instrument
Accuracy Grade
0.2%Rdg
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
7kg
Power Source
AC220V
Product Name
Transformer Turns Ratio TTR Instrument
Test Standards
IEC60076/IEC60044/ GB/T1094
Applicable to Transformer
Connected in Y Type, D Type
Ratio Measurement Range
1-10000
Phase Measurement Error
1 Degree
Turns Ratio Resolution
0.0001
Test Voltage
0-80V
Power Supply
AC220V±10%, 50Hz
Transport Package
Wooden Case
Specification
400*350*200mm
Trademark
GOLD
Origin
Chongqing, China
Production Capacity
200sets/Month

Product Description

Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester

Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester

Introduction

The ratio tester is used to test the ratio, polarity and wiring group of various transformers. It can identify the correctness of the transformer winding turn ratio, the state of the tap switch, whether there is an internal turn-to-turn short circuit or inter-layer short circuit, so as to determine whether the transformer can operate or run in parallel. The ratio tester is a new generation of intelligent ratio test instrument, with intuitive display, good stability, high accuracy and wide measurement range.

Features


1. Automatically measure transformer connection group.
2. Automatically switch range.
3. Automatically measure ratio of single or three phase transformer.
4. Automatically measure ratio of single or three phase voltage transformer.
5. Automatically measure the turn ratio and polarity of single phase CT and VT.
6. Calculate ratio error automatically.
7. Overload and reverse connection detect unit would prevent tester damaged in wrong connection mode.
8. Setting data and the test results are saved automatically. The history data can be recall again.
9. Print test results by micro printer
.

Technical Parameters
 
Applicable to transformer Connected in Y type,D type
Test standards IEC60076/IEC60044/ GB/T1094
Ratio measurement range 1-10000
Group measurement 1-12
Phase measurement error 1 degree
Ratio measurement error ±0.2%RDG(1-2000)
±0.5%RDG(2000-10000)
Turns ratio resolution 0.0001
Test voltage 0-80V
Power supply AC220V±10%, 50Hz
Size&Weight 580*450*360mm
Weight 22kg


Turns Ratio between the Windings

The power transformer turns ratio test is an AC low voltage test conducted to determine the ratio between the high voltage winding and all other windings when the transformer is unloaded. This test is performed on every tap of each individual winding to ensure accurate measurement.

Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
The Transformer Turns Ratio tester (TTR) is device used to measure the turns ratio between the windings (example shown below)

Connection Scheme

Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
Voltage is applied on the H marked leads and measured of the X marked lead by the test set.
Ratio measurements are conducted on all tap positions and calculated by dividing the induced voltage reading into the applied voltage value. When ratio tests are being made on three-phase transformers, the ratio is taken on one phase at a time with a three-phase TTR until the ratio measurements of all three phases are completed.

Connect the H0, H1, H2, and H3 test cables to the corresponding high-voltage winding terminals of the transformer under test. With delta connected windings, H0 is not used.
Connect the X0, X1, X2, and X3 test cables to the corresponding low-voltage winding of the transformer under test. With delta connected windings, X0 is not used.
It is possible to test single phase two-winding transformers with a three-phase TTR test set by only utilizing the H1, H2 and X1, X2 leads.

Accessories List
GDBC-901 Main unit 1 unit
Micro printer manual 1 unit
Power cable 1 unit
Certificate 1 unit
CD Disk 1 unit
User manual 1 unit
Test cable 2 unit
Ground cable 1 unit
Test report 1 unit
Fuse 2 unit
Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester

Common Trouble Shooting
 
LCD fonts are black or white Adjust the contrast potentiometer located at the bottom of the LCD until the fonts on LCD are clear.
The tester has no response Restart the power supply
The micro printer is not in work condition Cut off the power supply of the tester and restart the tester in 1 minute later

Details Picture
Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester
Transformer Turns Ratio Instrument TTR Single Phase Inspection Tester



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now