Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for CT PT Analyzer
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
  • Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
  • Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
  • Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
  • Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
  • Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
Find Similar Products

Basic Info.

Model NO.
GDVA-405 CT PT Analyzer
Power Supply
AC220V±10%, 50/60Hz±10%
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Power Output
500va
Max. Knee Voltage Measurement
45kv
Current Measurement Error
<±0.1%+0.01%Fs
Current Measurement Range
0~10A (Automatically Change Range in 0.1/0.4/2/10
Voltage Measurement Range
0~200V (Automatically Change Range in 1V/10V/70V/2
Voltage Measurement Error
< ±0.1%+0.01%Fs
Transport Package
Standard Plywood Case
Specification
20kg
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
1000PCS/Month

Product Description

Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT 


Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring

Application:


Tests for current transformer:

  • Excitation curve and parameters test

  • Turns ratio test

  • Ratio and phase error test

  • Polarity mark check

  • Winding resistance measurement

  • Secondary loop burden measurement

  • Error line curve test for protection CT

  • Transient CT parameters test

  • CT nameplate guess

  • Saturation hysteresis loop curve measurement

  • Tests for Potencial Transformer:

  • Turns ratio test

  • Ratio error and phase angle error test

  • Polarity test

  • Secondary burden test

  • Winding resistance test

Applications of CT/ PT Analyzer:

  • CT nameplate check

  • CT parameters check in work burden

  • CT transient parameters analysis

  • CT ratio and phase error calibration

  • PT routine test

 

Specifications:

Item Name Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT 
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply  AC220V±10%, 50/60Hz±10%
Voltage output  0.1~180V (AC)
Current output  0.001~5A(RMS)
Power output  500VA
Max.  knee voltage measurement  45KV
Current measurement
 
 
  Range 0~10A (automatically change  range in 0.1/0.4/2/10A)
  Error  <±0.1%+0.01%FS

 

Voltage measurement
 
 Range 0~200V (automatically change range in 1V/10V/70V/200V)
 Error < ±0.1%+0.01%FS
Turns ratio measurement Range
  
1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement   error  ±2min
resolution  0.01min
Winding resistance measurement
    
   
Range 0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error  < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement -50~100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error  <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
   
  
PT Secondary burden
 
Error 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Maximum <0.2%RDG+0.02%FS
resolution  0.1ohm
   
PT ratio measurement
Range

1~35000,

1~10000 error<0.1%, 

10000~35000 error<0.2%

PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity  >1000 groups test results
Working condition temperature  -10ºC~50ºC; moist ≤90%

Working On site:

Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
Testing Process:


Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring

Customer Visit 

Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
 
Exhibition
Portable Current Transformer Volt-Ampere Characteristic Tester Automatic CT PT Analyzer for All Kinds of CT PT Measuring
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier