Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids

Product Details
Customization: Available
After-sales Service: 2 Years
Warranty: 2 Years
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
  • Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
  • Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
  • Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
  • Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
  • Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
Find Similar Products
  • Overview
  • Summay
  • Features
  • Product Parameters
  • Detail Images
  • FAQ
  • Packaging
  • Service
  • Exhibition
Overview

Basic Info.

Model NO.
GDD-1A
Customized
Non-Customized
Structure
Desktop
Certification
ISO
Application
Lab
Type
Karl Fischer Titrator
Volumetric Karl Fischer Titrator
Test Water Content in Oil, Solvent, Chemicals, etc
Volumetric Titrator
Automatic
Karl Fischer Titration
Can Communication with PC, USB
Test Standard
ASTM D1533, ASTM D6304
Water Content Range
1ppm~100%
Measurement Range
0.001%-100% (Water Phase Content)
Size
370mm*250mm*170mm, 6kg
Maxcapacity
Volumetric Method Karl Fischer Moisture Titrator
Loading Method
Volumetric Method Karl Fischer Moisture Titrator
Display
Digital
End-Point Delay Time
10s-300S Adjustable Continuously
Transport Package
Packed in Plywood
Specification
64CM*52CM*44CM, 22KG
Trademark
GOLD
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
100 Sets/ Month

Product Description

Volumetric Karl Fischer Titrator



The volumetric karl fischer titrator adopts the newest mechanical-electronic technology with humanistic interface. It is reliable with wide measuring range (0.001%-100%), high precision and affordable for users. It can determine crystal water, adsorbent water in gas, liquid, solid samples.
It can automatically analyze, absorb and discharge liquid, adjust instrument failure, protect important parts, calibrate electrode parameters, etc.  
Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids

Summay

There are two different techniques for water determination by Karl Fischer Titration: Volumetric KF titration and Coulometric KF titration.

1. The Volumetric Karl Fischer Titration is suitable for determination of water content down to 1% of water. The sample is dissolved in Karl Fischer Solvent (usually methanol based) and the iodine is added as a part of a KF Reagent containing sulfur dioxide and iodine dissolved in pyridine and methanol. The endpoint is determined potentiometrically.
2. The Coulometric Karl Fischer analysis requires only one, iodide-containing, solution. Iodine needed for KF reaction is produced by anodic oxidation of iodide from solution and the endpoint is detected electrochemically. Coulometric determination is best suited for samples with less than 1% of water.


The GDD-1A Volumetric Karl Fisher Titrator adopts the newest mechanical-electronic technology with humanistic interface. It is reliable with wide measuring range (0.001%-100%), high precision and affordable for users. It can determine crystal water, adsorbent water in gas, liquid, solid samples.
Volumetric karl fischer titrator can automatically analyze, absorb and discharge liquid, adjust instrument failure, protect important parts, calibrate electrode parameters, etc.  

Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids

Features


1. Volumetric karl fischer titrator has dual platinum electrode polarization voltage to judge and show the reaction endpoint,then stop titration.
2. Fully sealed system, in order to avoid ambient moisture's penetration.
3. By the function keys,the instrument can absorb reagent, measure, show end point, absorb solvent, discharge waste fluid, stir and adjust speed. 
4. Displaying the mixed results simultaneously, titration dynamically display and automatic memory of test data.
5. Automatically deduct drifting value,automatically track the ambient moisture drifting and make sure the test data is precise.
6. The system is fully sealed,it can renew the solvent and discharge waste fluid  automatically, to avoid leak out toxic solvent.
7. Instrument status, dip stool sample volume, present time and drifting value,etc could be displayed instantly
8. The Karl Fisher Titrator runs smoothly, low noise.

Product Parameters

 

Item Index
Measurement range 0.001%-100% (water phase content)
Resolution 1μg
Titration repeatability ≤0.01
Titration linear coefficient ≥0.998
Error ≤2%
Test time 2-5min
Data storage 100 groups
Burette 200ml automatic burette
Titration accuracy 0.001ml
End-point delay time 10s-300s adjustable continuously
Power Supply 110~220V/50HZ
Gross weight 5.5kg
 

Detail Images

Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids
Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids

FAQ

  • Q: What about the delivery date?
    A: The test machine most are in stock, can delivery within 2-5 working days after received the payment. We can also accept the urgent order for prompt shipment.
    Q: What is the payment term?
    A: Payment by T/T, L/C ,Western Union and we suggest you company to pay online  by credit card and trade assurance.
  • Q: Do you support customizing service?
    A: Yes, we could customize the out package, machine's color, Logo and Voltage as request. With more than 12 years' production experience. We would give you an excellent experience! 

Packaging

Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids

Service

  • Installation and training
    1. If buyers visit our factory and check the machine, we will teach you how to install and use the
    machine, and also train your workers/technician face to face.
    2. Without visiting, we will send you user manual and video to teach you to install and operate.
    3. If buyer needs our technician to go to your local factory, please arrange board and lodging and other necessary things.
  • After-sales Service
    1.Two years guarantee for whole machine.
    2.24 hours technical support by email or calling
    3. If there is any problem found of the machine, we will repair it for free in two years.

Exhibition

Karl Fischer Method Volumetric Karl Fisher Titrator for Analysis of Water Content in Various Liquids

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now