• IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test
  • IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test
  • IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test
  • IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test
  • IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test
  • IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test

IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test

Warranty: 12 Months
Standard: IEC 60332-1-1,2,3; En 50086-1-1994
Sample: Signal Insulated Wire or Cable
Control System: Touch-Screen
Oversea Traning: Available
Transport Package: Plywood Case
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-IEC60332-1
Specification
36KG
Trademark
Gold
Origin
China
HS Code
9031809090
Production Capacity
20 Sets/Month

Product Description

      IEC 60332-1 Single Cable Vertical Flame Tester

IEC 60332-1 Automatical Flame Propagation Tester for Single Cable Flame Test


Introduction:

A single wire and cable combustion tester is used to test the flame retardant performance of the insulation layer of wire and cable under abnormal conditions such as overheating and overcurrent. It is applied to test the vertical flame spread of cable or cable, and it can also test the flame condition of the droplet.

The timing design of the tester meets the requirements of iec60332-1 and iec60332-2 blowtorch design. Test one set of a control system is equipped with two sets of test boxes and test lights; Can save most control costs as a customer. And achieve the purpose of design

Standard:

IEC 60332-1-1,2,3; EN 50086-1-1994

GBT 18380.11,12-2008
Application:
     Wire
    Cable

Main features:

  • Stainless steel box, the height of 1300mm, the width of 300mm, the depth of 450mm.

  • Two stainless steel rods can bind a single wire cable or optical cable samples.

  • 1KW mixed standard burner can provide the standard test fire source.

  • Regulating gas and airflow rate of the rotor flow meters.

  • Pressure gauge and pressure relief valve to ensure that the pressure output is 0.1MPA.

  • Electric spark ignition device.

  • Flame height measuring tool.

  • Up to four-time modes can be selected according to different sample diameters.

  • Calibration kit for the testing flame.

Specification:

Operating voltage

AC220 V ± 10V 50HZ

Ambient temperature

room temperature ~ 40 ºC

Gas Pressure

0.1MPa

Gas purity

Propane> 95%; compressed air

Timing Accuracy

0.1s

 Model

GD-IEC60332

 Size

600(W)×450(D)×1250(H)mm

 Power

AC 220V, 50/60Hz, 3A

 Weight

60kg

 Manual

Provide

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters